Các lỗi thường gặp

Code :
  • Code: 49.02.01:07
  • Description: Left or right bar aerosol removal filter almost full. Replace it with a new one as soon as possible.
  • Causes:
  • Remedy: Run subsystem diagnostic.
  • Code: 49.02.01:09
  • Description: Left or right bar aerosol removal filter not present. Check that the filter is in place. If the filter is already installed, run diagnostic.
  • Causes: Having set high fan PWM pressure, the value is low.
  • Remedy: 1. Check that the filter is present. 2. Check the box sealing. 3. Run subsystem diagnostic.
  • Code: 49.02.02:02
  • Description: Left or right bar aerosol removal nozzle clog detected. Ensure that aerosol removal air inlet is clean.
  • Causes: a. Nozzle/filter clogged b. Pressure sensor clogged/failing or connections damaged
  • Remedy: 1. Check and clean the inlet. 2. Check and/or replace the filter. 3. Check the pressure sensor and its connections.
  • Code: 49.02.02:07
  • Description: Left or right bar aerosol removal filter almost full. Replace it with a new one as soon as possible.
  • Causes:
  • Remedy: Run subsystem diagnostic.
  • Code: 49.02.02:09
  • Description: Left or right bar aerosol removal filter not present. Check that the filter is in place. If the filter is already installed, run diagnostic.
  • Causes: Having set high fan PWM pressure, the value is low.
  • Remedy: 1. Check that the filter is present. 2. Check the box sealing. 3. Run subsystem diagnostic.
  • Code: 49.03.01:09
  • Description: Left or right bar aerosol removal pressure sensor not connected. Run subsystem diagnostic to check them. If problem is confirmed call support.
  • Causes: a. Pressure sensor tube is not connected. b. Pressure sensor is not connected to Sinatra PCA. c. Sinatra PCA is failing.
  • Remedy: 1. Run subsystem diagnostic. 2. Check tube connection. 3. Check sensor cable. 4. Replace Sinatra PCA.
  • Code: 49.03.01:31
  • Description: Left or right bar aerosol removal negative pressure detected. Run subsystem diagnostic.
  • Causes: a. The pressure sensor tube is connected to the wrong side of the sensor. b. The pressure sensor is failing. c. The Sinatra PCA is failing. d. The aerosol fan is installed in the reverse direction.
  • Remedy: 1. Run subsystem diagnostic. 2. Check that the pressure sensor tube is in the right position. 3. Check that the pressure sensor is working. 4. The drying PCA is failing, run drying diagnostics before replacing it. 5. Check that the aerosol fans are correctly installed.
  • Code: 49.03.01:32
  • Description: Left or right bar aerosol removal pressure value too high. Run subsystem diagnostic.
  • Causes: The pressure value is out of the pressure sensor range of measurement.
  • Remedy: 1. Run subsystem diagnostic. 2. Replace the pressure sensor. 3. Replace the Sinatra PCA.