Các lỗi thường gặp

Code :
  • Code: 49.03.01:33
  • Description: Left or right bar aerosol removal pressure value too low. Run subsystem diagnostic.
  • Causes: The most probable cause of this error is that the tube that connects the pressure sensor (Sensirion SDP1000- L05) to the aerosol removal box is disconnected or pinched. The sensor is located near the right bar aerosol removal box, and the tube should be connected from the sensor inlet marked as Lo to the inlet at the bottom of the aerosol removal box: œ The tube should not be pinched. œ The tube should go up to the full length of the inlets at the sensor and the box. If the tube is properly connected at both inlets, make sure that it is not pinched by any other element in the carriage. If the pressure sensor reading is too low, the aerosol removal bar will work at full power (the module will be very noisy) and there may be small errors in dot placement that could produce grain.
  • Remedy: 1. Run subsystem diagnostic. 2. Check that all tubes are properly connected and not pinched. 3. Check cable connections. 4. Replace the sensor.
  • Code: 49.03.02:09
  • Description: Left or right bar aerosol removal pressure sensor not connected. Run subsystem diagnostic to check them. If problem is confirmed call support
  • Causes: a. Pressure sensor tube is not connected. b. Pressure sensor is not connected to Sinatra PCA. c. Sinatra PCA is failing.
  • Remedy: 1. Run subsystem diagnostic. 2. Check tube connection. 3. Check sensor cable. 4. Replace the Sinatra PCA.
  • Code: 49.03.02:31
  • Description: Left or right bar aerosol removal negative pressure detected. Run subsystem diagnostic.
  • Causes: a. The pressure sensor tube is connected to the wrong side of the sensor. b. The pressure sensor is failing. c. The Sinatra PCA is failing. d. The aerosol fan is installed in the reverse direction.
  • Remedy: 1. Run subsystem diagnostic. 2. Check that the pressure sensor tube is in the right position. 3. Check that the pressure sensor is working. 4. The drying PCA is failing, run drying diagnostics before replacing it. 5. Check that the aerosol fans are correctly installed.
  • Code: 49.03.02:32
  • Description: Left or right bar aerosol removal pressure value too high. Run subsystem diagnostic.
  • Causes: The pressure value is out of the pressure sensor range of measurement.
  • Remedy: 1. Run subsystem diagnostic. 2. Replace the pressure sensor. 3. Replace the Sinatra PCA.
  • Code: 49.03.02:33
  • Description: Left or right bar aerosol removal pressure value too low. Run subsystem diagnostic.
  • Causes: The most probable cause of this error is that the tube that connects the pressure sensor (Sensirion SDP1000- L05) to the aerosol removal box is disconnected or pinched. The sensor is located near the right bar aerosol removal box, and the tube should be connected from the sensor inlet marked as Lo to the inlet at the bottom of the aerosol removal box: œ The tube should not be pinched. œ The tube should go up to the full length of the inlets at the sensor and the box. If the tube is properly connected at both inlets, make sure that it is not pinched by any other element in the carriage. If the pressure sensor reading is too low, the aerosol removal bar will work at full power (the module will be very noisy) and there may be small errors in dot placement that could produce grain.
  • Remedy: 1. Run subsystem diagnostic. 2. Check that all tubes are properly connected and not pinched. 3. Check cable connections. 4. Replace the sensor.
  • Code: 50.00.01:00
  • Description: OMAS is not tracking substrate. This error is triggered when the OMAS is disconnected as the result of a failed calibration or repeated navigation failures during a plot. The error is logged in a file.
  • Causes: a. Substrate not navigable b. OMAS window dirty c. OMAS failure
  • Remedy: 1. Check whether the substrate type is transparent or lacks sufficient features to be read by the OMAS. If this is the case, turn off the OMAS for that substrate type. 2. Clean the OMAS window. See the user’s guide. 3. Replace the OMAS platen assembly
  • Code: 50.00.01:89
  • Description: Double-sided only, cannot find the registration line. Reload substrate. If error persists, run diagnostics.
  • Causes: a. Substrate bubble b. Dirty sensor c. Faulty sensor
  • Remedy: 1. Check that the substrate is navigable, properly loaded, and flat over the sensor. 2. Run the OMAS cleanliness diagnostic and clean it if necessary. 3. Replace the OMAS.
  • Code: 50.01.01:00
  • Description: OMAS doesn't see fiducials.
  • Causes: a. Substrate bubble b. Dirty sensor c. Faulty sensor
  • Remedy: 1. Check that the substrate is navigable, properly loaded, and flat over the sensor. 2. Run the OMAS cleanliness diagnostic and clean it if necessary. 3. Replace the OMAS.