Code: 14.81:10

Description: Curing power regulator current too high
Causes: Heaters, Heater Control.
Remedy: Service engineer: 1. Run Service "Curing system monitor". 2. Check heaters with a tester and replace heaters if necessary (shortcut). 3. Replace the Heater Control.

Code: 14.82:10

Description: Curing power regulator shortcut
Causes: Heaters, Heater Control.
Remedy: Service engineer: 1. Run Service "Curing system monitor". 2. Check heaters with a tester and replace heaters if necessary (shortcut). 3. Replace the Heater Control.

Code: 14.83:11

Description: Curing power regulator open circuit
Causes: Heater Control to Curing Power Interconnect PCA Cable. Curing Power Interconnect PCA Curing Cable. Curing Resistor.
Remedy: Service engineer: 1. Run Service "Curing system monitor". 2. Reseat/Replace the Heater Control to Curing Power Interconnect PCA Cables. 3. Reseat/Replace Curing Power Interconnect PCA Curing Cable. 4. Reseat/Replace all Curing Resistors connectors.

Code: 14.87:10

Description: Curing power regulator OverTemp
Causes: Power regulator OverTemp.
Remedy: Service engineer: 1. Run Service "Curing system monitor". 2. If the SE appears frequently, replace the Heater Control.

Code: 14.88:10

Description: Curing power regulator overvoltage or shortcut
Causes: Regulator overvoltage or shortcut.
Remedy: Service engineer: 1. Run Service "Curing system monitor". 2. Check resistor module values, If they are ok, check installation.

Code: 14.89:10

Description: Curing power regulator relay damaged
Causes: Heater Control.
Remedy: Service engineer: 1. Run Service "Curing system monitor". 2. Replace de Heater Control.

Code: 15.20:10

Description: Cable or Resistor shortcircuit from any PZ or vapor resistor
Causes: Shortcircuit from Any PZ or vapor resistor.
Remedy: Service engineer: • Check the PZ resistors, the Vapor resistors, or cable shortcircuits. Replace the affected part.

Code: 15.31:10

Description: PZ resistor 1: Cable or resistor shortcircuit
Causes: Cable or resistor shortcircuit.
Remedy: Service engineer: • Check the PZ resistor 1 or cable shortcircuit.