Các lỗi thường gặp

Code :
  • Code: 12.2:10
  • Description: Printmech 24V_BULLI_1 to Curing module PCA out of range
  • Causes: The 24V cable from Printmech to Curing Control PCA has a problem. Printmech PCA is damaged.
  • Remedy: Call agent: • Restart the printer. Service engineer: 1. Check the Printmech cable to the Curing module PCA. 2. Check the Printmech PCA.
  • Code: 12.30:10
  • Description: Printmech: 24V to Interconnect open circuit. Check TUR, Right aerosol fan and Primer valves
  • Causes: The 24V cable from Printmech to Interconnect PCA has a problem Printmech PCA is damaged.
  • Remedy: Call agent: • Restart the printer. Service engineer: 1. Check the Printmech to Interconnect cable. 2. Check the TUR, Right aerosol fan, and Primer valves. 3. Check the Printmech PCA.
  • Code: 12.31:10
  • Description: Printmech: 24V Misc open circuit. Check Air pumps and Primer valves switch
  • Causes: The 24V cable from Printmech to Air Pumps and Interconnect PCA has a problem Printmech PCA is damaged.
  • Remedy: Call agent: • Restart the printer. Service engineer: 1. Check the Printmech to Air Pumps and to primer valves switch cable. 2. Check the Air Pumps. 3. Check the Primer valves switch. 4. Check the Printmech PCA.
  • Code: 12.32:10
  • Description: Printmech: 24V to Printzone fans open circuit
  • Causes: The 24V cable from Printmech to Printzone fans has a problem Printmech PCA is damaged.
  • Remedy: Call agent: • Restart the printer. Service engineer: 1. Check the Printmech to Printzone fans cable. 2. Check the Printzone fans. 3. Check the Printmech PCA.
  • Code: 12.33:10
  • Description: Printmech: 24V to Vacuum fans open circuit
  • Causes: The 24V cable from Printmech to Vacuum fans has a problem Printmech PCA is damaged.
  • Remedy: Call agent: • Restart the printer. Service engineer: 1. Check the Printmech to Vacuum fans cable. 2. Check the Vacuum fans. 3. Check the Printmech PCA.
  • Code: 12.34:10
  • Description: Printmech: 42V to Paper motor open circuit
  • Causes: The 42V cable from Printmech to Paper motor has a problem Printmech PCA is damaged.
  • Remedy: Call agent: • Restart the printer. Service engineer: 1. Check the Printmech to Paper motor cable. 2. Check the paper motor. 3. Check the Printmech PCA.
  • Code: 12.35:10
  • Description: Printmech: 42V to Rewinder open circuit
  • Causes: The 42V cable from Printmech to Rewinder has a problem Printmech PCA is damaged.
  • Remedy: Call agent: • Restart the printer. Service engineer: 1. Check the Printmech to Rewinder cable. 2. Check the Rewinder. 3. Check the Printmech PCA.
  • Code: 12.36:10
  • Description: Printmech: 42V to Scan motor open circuit
  • Causes: The 42V cable from Printmech to Scan motor has a problem Printmech PCA is damaged.
  • Remedy: Call agent: • Restart the printer. Service engineer: 1. Check the Printmech to Scan motor cable. 2. Check the Scan motor. 3. Check the Printmech PCA.
‹ First  < 3 4 5 6 7 8 9 >  Last ›
popup

Số lượng:

Tổng tiền:

Danh mục