Các lỗi thường gặp

Code :
  • Code: 12.9:10
  • Description: Printmech: Hannibal3 24V failure. Check Inner lights array 1
  • Causes: The 24V cable from Printmech to Inner lights array 1 has a problem Printmech PCA is damaged.
  • Remedy: Call agent: • Restart the printer. Service engineer: 1. Check the Inner lights array 1. 2. Check the Printmech PCA.
  • Code: 13.3:10
  • Description: Printmech 12V_BULLI_2 to Vapor Removal PCA out of range
  • Causes: The Printmech 12V_BULLI_2 to Vapor Removal PCA is out of range.
  • Remedy: Call agent: • Restart the printer. Service engineer: 1. Check the Printmech cable to Vapor Removal PCA. 2. Check the Printmech PCA.
  • Code: 14.73:01
  • Description: Curing power regulator V lower than 60: V lower than 60
  • Causes: Heater Control AC Input (RCCB, AC Voltage Outlet, AC Power Cord) Heater Control.
  • Remedy: Call agent: 1. Check that both Residual Circuit Breakers (RCCBs) are Powered and ON. 2. Check/Reseat both Power Cords. Service engineer: 1. Check AC Voltage at customer's site (180-264Vac). 2. Reseat/Replace cables to Heater Control's AC input. 3. Replace the Heater Control.
  • Code: 14.74:01
  • Description: Curing power regulator V lower than 140
  • Causes: V lower than 140
  • Remedy: Service engineer: 1. Run Service "Curing system monitor". 2. Check the input voltage.
  • Code: 14.75:01
  • Description: Curing power regulator V bigger than Vmax
  • Causes: V bigger than Vmax
  • Remedy: 1. Check the input voltage. 2. Run Service "Curing system monitor".
  • Code: 14.76:11
  • Description: Curing power regulator V could not be read
  • Causes: Curing Control PCA Cable to Heater Control.
  • Remedy: Service engineer: 1. Run Service "Curing system monitor". 2. Reseat/Replace Curing Control PCA Cable to Heater Control.
  • Code: 14.77:10
  • Description: Curing power regulator control signal failure
  • Causes: Control signal failure
  • Remedy: Service engineer: • Replace the Control PCA to Heater Control and Control PCA cables.
  • Code: 14.80:10
  • Description: Curing power regulator current not null
  • Causes: Heater Control.
  • Remedy: Service engineer: 1. Run Service "Curing system monitor". 2. Replace the Heater Control.