Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi Konica-Minolta bizhub 4050 — Trang 7/27

Code: 2564-132.02

Description: Black TCR sensor failure
TDS baseline too high.
Causes: • Toner density sensor (PS13) • Controller board (CTLB)
Remedy: 1 Remove the transfer roll, and then check for loose toner blocking PS13. Clean the sensor if any abnormality is found. 2 Check PS13 for proper operation. Reinstall the actuator if any abnormality is found. 3 If it still cannot move freely, then replace PS13. 4 Check the cable JTDS for proper connection. Reseat the cable if any abnormality is found. 5 Check the cable JTDS for damage and pinch points. Replace PS13 if any abnormality is found. 6 Replace the CTLB.

Code: 2564-132.03

Description: Black TCR sensor failure
TDS baseline excessive range.
Causes: • Toner density sensor (PS13) • Controller board (CTLB)
Remedy: 1 Remove the transfer roll, and then check for loose toner blocking PS13. Clean the sensor if any abnormality is found. 2 Check PS13 for proper operation. Reinstall the actuator if any abnormality is found. 3 If it still cannot move freely, then replace PS13. 4 Check the cable JTDS for proper connection. Reseat the cable if any abnormality is found. 5 Check the cable JTDS for damage and pinch points. Replace PS13 if any abnormality is found. 6 Replace the CTLB.

Code: 2564-132.16

Description: Black TCR sensor failure
TDS calibration at maximum.
Causes: • Toner density sensor (PS13) • Controller board (CTLB)
Remedy: 1 Remove the transfer roll, and then check for loose toner blocking PS13. Clean the sensor if any abnormality is found. 2 Check PS13 for proper operation. Reinstall the actuator if any abnormality is found. 3 If it still cannot move freely, then replace PS13. 4 Check the cable JTDS for proper connection. Reseat the cable if any abnormality is found. 5 Check the cable JTDS for damage and pinch points. Replace PS13 if any abnormality is found. 6 Replace the CTLB.

Code: 2564-132.17

Description: Black TCR sensor failure
TDS calibration too low.
Causes: • Toner density sensor (PS13) • Controller board (CTLB)
Remedy: 1 Remove the transfer roll, and then check for loose toner blocking PS13. Clean the sensor if any abnormality is found. 2 Check PS13 for proper operation. Reinstall the actuator if any abnormality is found. 3 If it still cannot move freely, then replace PS13. 4 Check the cable JTDS for proper connection. Reseat the cable if any abnormality is found. 5 Check the cable JTDS for damage and pinch points. Replace PS13 if any abnormality is found. 6 Replace the CTLB.

Code: 2564-132.18

Description: Black TCR sensor failure
TDS calibration too close to baseline.
Causes: • Toner density sensor (PS13) • Controller board (CTLB)
Remedy: 1 Remove the transfer roll, and then check for loose toner blocking PS13. Clean the sensor if any abnormality is found. 2 Check PS13 for proper operation. Reinstall the actuator if any abnormality is found. 3 If it still cannot move freely, then replace PS13. 4 Check the cable JTDS for proper connection. Reseat the cable if any abnormality is found. 5 Check the cable JTDS for damage and pinch points. Replace PS13 if any abnormality is found. 6 Replace the CTLB.

Code: 2564-132.32

Description: Black TCR sensor failure
PC drum measurement too high.
Causes: • Toner density sensor (PS13) • Controller board (CTLB)
Remedy: 1 Remove the transfer roll, and then check for loose toner blocking PS13. Clean the sensor if any abnormality is found. 2 Check PS13 for proper operation. Reinstall the actuator if any abnormality is found. 3 If it still cannot move freely, then replace PS13. 4 Check the cable JTDS for proper connection. Reseat the cable if any abnormality is found. 5 Check the cable JTDS for damage and pinch points. Replace PS13 if any abnormality is found. 6 Replace the CTLB.

Code: 2564-132.33

Description: Black TCR sensor failure
PC drum measurement too different from calibration.
Causes: • Toner density sensor (PS13) • Controller board (CTLB)
Remedy: 1 Remove the transfer roll, and then check for loose toner blocking PS13. Clean the sensor if any abnormality is found. 2 Check PS13 for proper operation. Reinstall the actuator if any abnormality is found. 3 If it still cannot move freely, then replace PS13. 4 Check the cable JTDS for proper connection. Reseat the cable if any abnormality is found. 5 Check the cable JTDS for damage and pinch points. Replace PS13 if any abnormality is found. 6 Replace the CTLB.

Code: 2564-132.34

Description: Black TCR sensor failure
PC drum measurement too close to baseline.
Causes: • Toner density sensor (PS13) • Controller board (CTLB)
Remedy: 1 Remove the transfer roll, and then check for loose toner blocking PS13. Clean the sensor if any abnormality is found. 2 Check PS13 for proper operation. Reinstall the actuator if any abnormality is found. 3 If it still cannot move freely, then replace PS13. 4 Check the cable JTDS for proper connection. Reseat the cable if any abnormality is found. 5 Check the cable JTDS for damage and pinch points. Replace PS13 if any abnormality is found. 6 Replace the CTLB.
Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie