Description: Black TCR sensor failure
TDS baseline too high.
Causes: • Toner density sensor (PS13) • Controller board (CTLB)
Remedy: 1 Remove the transfer roll, and then check for loose toner blocking PS13. Clean the sensor if any abnormality is found. 2 Check PS13 for proper operation. Reinstall the actuator if any abnormality is found. 3 If it still cannot move freely, then replace PS13. 4 Check the cable JTDS for proper connection. Reseat the cable if any abnormality is found. 5 Check the cable JTDS for damage and pinch points. Replace PS13 if any abnormality is found. 6 Replace the CTLB.
Code: 2564-132.03
Description: Black TCR sensor failure
TDS baseline excessive range.
Causes: • Toner density sensor (PS13) • Controller board (CTLB)
Remedy: 1 Remove the transfer roll, and then check for loose toner blocking PS13. Clean the sensor if any abnormality is found. 2 Check PS13 for proper operation. Reinstall the actuator if any abnormality is found. 3 If it still cannot move freely, then replace PS13. 4 Check the cable JTDS for proper connection. Reseat the cable if any abnormality is found. 5 Check the cable JTDS for damage and pinch points. Replace PS13 if any abnormality is found. 6 Replace the CTLB.
Code: 2564-132.16
Description: Black TCR sensor failure
TDS calibration at maximum.
Causes: • Toner density sensor (PS13) • Controller board (CTLB)
Remedy: 1 Remove the transfer roll, and then check for loose toner blocking PS13. Clean the sensor if any abnormality is found. 2 Check PS13 for proper operation. Reinstall the actuator if any abnormality is found. 3 If it still cannot move freely, then replace PS13. 4 Check the cable JTDS for proper connection. Reseat the cable if any abnormality is found. 5 Check the cable JTDS for damage and pinch points. Replace PS13 if any abnormality is found. 6 Replace the CTLB.
Code: 2564-132.17
Description: Black TCR sensor failure
TDS calibration too low.
Causes: • Toner density sensor (PS13) • Controller board (CTLB)
Remedy: 1 Remove the transfer roll, and then check for loose toner blocking PS13. Clean the sensor if any abnormality is found. 2 Check PS13 for proper operation. Reinstall the actuator if any abnormality is found. 3 If it still cannot move freely, then replace PS13. 4 Check the cable JTDS for proper connection. Reseat the cable if any abnormality is found. 5 Check the cable JTDS for damage and pinch points. Replace PS13 if any abnormality is found. 6 Replace the CTLB.
Code: 2564-132.18
Description: Black TCR sensor failure
TDS calibration too close to baseline.
Causes: • Toner density sensor (PS13) • Controller board (CTLB)
Remedy: 1 Remove the transfer roll, and then check for loose toner blocking PS13. Clean the sensor if any abnormality is found. 2 Check PS13 for proper operation. Reinstall the actuator if any abnormality is found. 3 If it still cannot move freely, then replace PS13. 4 Check the cable JTDS for proper connection. Reseat the cable if any abnormality is found. 5 Check the cable JTDS for damage and pinch points. Replace PS13 if any abnormality is found. 6 Replace the CTLB.
Code: 2564-132.32
Description: Black TCR sensor failure
PC drum measurement too high.
Causes: • Toner density sensor (PS13) • Controller board (CTLB)
Remedy: 1 Remove the transfer roll, and then check for loose toner blocking PS13. Clean the sensor if any abnormality is found. 2 Check PS13 for proper operation. Reinstall the actuator if any abnormality is found. 3 If it still cannot move freely, then replace PS13. 4 Check the cable JTDS for proper connection. Reseat the cable if any abnormality is found. 5 Check the cable JTDS for damage and pinch points. Replace PS13 if any abnormality is found. 6 Replace the CTLB.
Code: 2564-132.33
Description: Black TCR sensor failure
PC drum measurement too different from calibration.
Causes: • Toner density sensor (PS13) • Controller board (CTLB)
Remedy: 1 Remove the transfer roll, and then check for loose toner blocking PS13. Clean the sensor if any abnormality is found. 2 Check PS13 for proper operation. Reinstall the actuator if any abnormality is found. 3 If it still cannot move freely, then replace PS13. 4 Check the cable JTDS for proper connection. Reseat the cable if any abnormality is found. 5 Check the cable JTDS for damage and pinch points. Replace PS13 if any abnormality is found. 6 Replace the CTLB.
Code: 2564-132.34
Description: Black TCR sensor failure
PC drum measurement too close to baseline.
Causes: • Toner density sensor (PS13) • Controller board (CTLB)
Remedy: 1 Remove the transfer roll, and then check for loose toner blocking PS13. Clean the sensor if any abnormality is found. 2 Check PS13 for proper operation. Reinstall the actuator if any abnormality is found. 3 If it still cannot move freely, then replace PS13. 4 Check the cable JTDS for proper connection. Reseat the cable if any abnormality is found. 5 Check the cable JTDS for damage and pinch points. Replace PS13 if any abnormality is found. 6 Replace the CTLB.