Causes: • PF control board (PFCB) • Controller board (CTLB)
Remedy: 1 Check all connections to the PFCB. Reseat the cables if any abnormality is found. 2 Check printer’s firmware level. Rewrite the firmware if any abnormality is found. 3 Replace the tray 3. 4 Replace the CTLB.
Causes: • PF control board (PFCB) • Controller board (CTLB)
Remedy: 1 Check all connections to the PFCB. Reseat the cables if any abnormality is found. 2 Check printer’s firmware level. Rewrite the firmware if any abnormality is found. 3 Replace the tray 3. 4 Replace the CTLB.
Description: Tray 3 lift-up failure
Hardware error - Sensors are not plugged on the board
Causes: • PF control board (PFCB) • Controller board (CTLB)
Remedy: 1 Check all connections to the PFCB. Reseat the cables if any abnormality is found. 2 Check printer’s firmware level. Rewrite the firmware if any abnormality is found. 3 Replace the tray 3. 4 Replace the CTLB.
Description: Tray 4 lift-up failure
ACM motor no first encoder
Causes: • ACM motor • PF control board (PFCB)
Remedy: 1 Remove the option tray insert. 2 Check the lift plate and gears for proper operation by moving the metal plate. Replace the tray 4 if any abnormality is found. 3 Check the ACM motor for the following: • Gear tooth breakage • Freedom of rotation Replace the tray 4 if any abnormality is found. 4 Check the cable J11 on PFCB. Replace the tray 4 if any abnormality is found.
Description: Tray 4 lift-up failure
ACM motor stop error
Causes: • ACM motor • PF control board (PFCB)
Remedy: 1 Remove the option tray insert. 2 Check the lift plate and gears for proper operation by moving the metal plate. Replace the tray 4 if any abnormality is found. 3 Check the ACM motor for the following: • Gear tooth breakage • Freedom of rotation Replace the tray 4 if any abnormality is found. 4 Check the cable J11 on PFCB. Replace the tray 4 if any abnormality is found.
Remedy: 1 Remove the option tray insert. 2 Check the lift plate and gears for proper operation by moving the metal plate. Replace the tray 4 if any abnormality is found. 3 Check the ACM motor for the following: • Gear tooth breakage • Freedom of rotation Replace the tray 4 if any abnormality is found. 4 Check the cable J11 on PFCB. Replace the tray 4 if any abnormality is found.
Description: Tray 4 lift-up failure
Separator/pass-through motor no first encoder
Causes: • PF control board (PFCB) • Separator roll assembly
Remedy: 1 Remove the option tray insert. 2 Check the separator roll assembly gear under the tray base for the following: • Gear tooth breakage • Freedom of rotation Replace the tray if any abnormality is found. 3 Check the cable J10 on PFCB. 4 Check the separator roll assembly for wear or damage. Replace the separator roll assembly if any abnormality is found.
Description: Tray 4 lift-up failure
Separator/pass-through motor stop error
Causes: • PF control board (PFCB) • Separator roll assembly
Remedy: 1 Remove the option tray insert. 2 Check the separator roll assembly gear under the tray base for the following: • Gear tooth breakage • Freedom of rotation Replace the tray if any abnormality is found. 3 Check the cable J10 on PFCB. 4 Check the separator roll assembly for wear or damage. Replace the separator roll assembly if any abnormality is found.
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.