Code: 0206-335.61

Description: Tray 3 lift-up failure
Hardware error - Option type unknown
Causes: • PF control board (PFCB) • Controller board (CTLB)
Remedy: 1 Check all connections to the PFCB. Reseat the cables if any abnormality is found. 2 Check printer’s firmware level. Rewrite the firmware if any abnormality is found. 3 Replace the tray 3. 4 Replace the CTLB.

Code: 0206-335.62

Description: Tray 3 lift-up failure
Hardware error - Product ID unknown
Causes: • PF control board (PFCB) • Controller board (CTLB)
Remedy: 1 Check all connections to the PFCB. Reseat the cables if any abnormality is found. 2 Check printer’s firmware level. Rewrite the firmware if any abnormality is found. 3 Replace the tray 3. 4 Replace the CTLB.

Code: 0206-335.63

Description: Tray 3 lift-up failure
Hardware error - Sensors are not plugged on the board
Causes: • PF control board (PFCB) • Controller board (CTLB)
Remedy: 1 Check all connections to the PFCB. Reseat the cables if any abnormality is found. 2 Check printer’s firmware level. Rewrite the firmware if any abnormality is found. 3 Replace the tray 3. 4 Replace the CTLB.

Code: 0208-341.51

Description: Tray 4 lift-up failure
ACM motor no first encoder
Causes: • ACM motor • PF control board (PFCB)
Remedy: 1 Remove the option tray insert. 2 Check the lift plate and gears for proper operation by moving the metal plate. Replace the tray 4 if any abnormality is found. 3 Check the ACM motor for the following: • Gear tooth breakage • Freedom of rotation Replace the tray 4 if any abnormality is found. 4 Check the cable J11 on PFCB. Replace the tray 4 if any abnormality is found.

Code: 0208-341.52

Description: Tray 4 lift-up failure
ACM motor stop error
Causes: • ACM motor • PF control board (PFCB)
Remedy: 1 Remove the option tray insert. 2 Check the lift plate and gears for proper operation by moving the metal plate. Replace the tray 4 if any abnormality is found. 3 Check the ACM motor for the following: • Gear tooth breakage • Freedom of rotation Replace the tray 4 if any abnormality is found. 4 Check the cable J11 on PFCB. Replace the tray 4 if any abnormality is found.

Code: 0208-341.53

Description: Tray 4 lift-up failure
ACM motor PWM underflow (motor overspeed)
Causes: • ACM motor • PF control board (PFCB)
Remedy: 1 Remove the option tray insert. 2 Check the lift plate and gears for proper operation by moving the metal plate. Replace the tray 4 if any abnormality is found. 3 Check the ACM motor for the following: • Gear tooth breakage • Freedom of rotation Replace the tray 4 if any abnormality is found. 4 Check the cable J11 on PFCB. Replace the tray 4 if any abnormality is found.

Code: 0208-342.54

Description: Tray 4 lift-up failure
Separator/pass-through motor no first encoder
Causes: • PF control board (PFCB) • Separator roll assembly
Remedy: 1 Remove the option tray insert. 2 Check the separator roll assembly gear under the tray base for the following: • Gear tooth breakage • Freedom of rotation Replace the tray if any abnormality is found. 3 Check the cable J10 on PFCB. 4 Check the separator roll assembly for wear or damage. Replace the separator roll assembly if any abnormality is found.

Code: 0208-342.55

Description: Tray 4 lift-up failure
Separator/pass-through motor stop error
Causes: • PF control board (PFCB) • Separator roll assembly
Remedy: 1 Remove the option tray insert. 2 Check the separator roll assembly gear under the tray base for the following: • Gear tooth breakage • Freedom of rotation Replace the tray if any abnormality is found. 3 Check the cable J10 on PFCB. 4 Check the separator roll assembly for wear or damage. Replace the separator roll assembly if any abnormality is found.