Các lỗi thường gặp

Code :
  • Code: 0206-331.53
  • Description: Tray 3 lift-up failure
    ACM motor PWM underflow (motor overspeed)
  • Causes: • ACM motor • PF control board (PFCB)
  • Remedy: 1 Remove the option tray insert. 2 Check the lift plate and gears for proper operation by moving the metal plate. Replace the tray 3 if any abnormality is found. 3 Check the ACM motor for the following: • Gear tooth breakage • Freedom of rotation Replace the tray 3 if any abnormality is found. 4 Check the cable J11 on PFCB. Replace the tray 3 if any abnormality is found.
  • Code: 0206-332.54
  • Description: Tray 3 lift-up failure
    Separator/Pass-through motor - Motor no first encoder
  • Causes: • PF control board (PFCB) • Separator roll assembly
  • Remedy: 1 Remove the option tray insert. 2 Check the separator roll assembly gear under the tray base for the following: • Gear tooth breakage • Freedom of rotation Replace the tray 3 if any abnormality is found. 3 Check the cable J10 on PFCB. Replace the tray 3 if any abnormality is found. 4 Check the separator roll assembly for wear or damage. Replace the separator roll assembly if any abnormality is found.
  • Code: 0206-332.55
  • Description: Tray 3 lift-up failure
    Separator/Pass-through motor - Motor stop error
  • Causes: • PF control board (PFCB) • Separator roll assembly
  • Remedy: 1 Remove the option tray insert. 2 Check the separator roll assembly gear under the tray base for the following: • Gear tooth breakage • Freedom of rotation Replace the tray 3 if any abnormality is found. 3 Check the cable J10 on PFCB. Replace the tray 3 if any abnormality is found. 4 Check the separator roll assembly for wear or damage. Replace the separator roll assembly if any abnormality is found.
  • Code: 0206-332.56
  • Description: Tray 3 lift-up failure
    Separator/Pass-through motor - PWM underflow (motor overspeed)
  • Causes: • PF control board (PFCB) • Separator roll assembly
  • Remedy: 1 Remove the option tray insert. 2 Check the separator roll assembly gear under the tray base for the following: • Gear tooth breakage • Freedom of rotation Replace the tray 3 if any abnormality is found. 3 Check the cable J10 on PFCB. Replace the tray 3 if any abnormality is found. 4 Check the separator roll assembly for wear or damage. Replace the separator roll assembly if any abnormality is found.
  • Code: 0206-334.57
  • Description: Tray 3 lift-up failure
    ACM motor no first encoder
  • Causes: • PF control board (PFCB) • Tray present sensor (PS35) • ACM assembly
  • Remedy: 1 Check the cable J11 on PFCB. Reseat the cable if any abnormality is found. 2 Remove the option tray insert and bypass PS35. 3 Enter the Service Mode and conduct a Paper Passage Test: Select [Service Mode] -> [State Confirmation] -> [Paper Passage Test] -> [Tray 3], and press the Start key. 4 Check the ACM for proper operation. Replace the ACM assembly if any abnormality is found. 5 Check the ACM gear for any wear or damage. Replace the ACM assembly if any abnormality is found.
  • Code: 0206-334.58
  • Description: Tray 3 lift-up failure
    ACM motor stop error
  • Causes: • PF control board (PFCB) • Tray present sensor (PS35) • ACM assembly
  • Remedy: 1 Check the cable J11 on PFCB. Reseat the cable if any abnormality is found. 2 Remove the option tray insert and bypass PS35. 3 Enter the Service Mode and conduct a Paper Passage Test: Select [Service Mode] -> [State Confirmation] -> [Paper Passage Test] -> [Tray 3], and press the Start key. 4 Check the ACM for proper operation. Replace the ACM assembly if any abnormality is found. 5 Check the ACM gear for any wear or damage. Replace the ACM assembly if any abnormality is found.
  • Code: 0206-334.59
  • Description: Tray 3 lift-up failure
    ACM PWM underflow (motor overspeed)
  • Causes: • PF control board (PFCB) • Tray present sensor (PS35) • ACM assembly
  • Remedy: 1 Check the cable J11 on PFCB. Reseat the cable if any abnormality is found. 2 Remove the option tray insert and bypass PS35. 3 Enter the Service Mode and conduct a Paper Passage Test: Select [Service Mode] -> [State Confirmation] -> [Paper Passage Test] -> [Tray 3], and press the Start key. 4 Check the ACM for proper operation. Replace the ACM assembly if any abnormality is found. 5 Check the ACM gear for any wear or damage. Replace the ACM assembly if any abnormality is found.
  • Code: 0206-335.60
  • Description: Tray 3 lift-up failure
    Hardware error - Board ID unknown
  • Causes: • PF control board (PFCB) • Controller board (CTLB)
  • Remedy: 1 Check all connections to the PFCB. Reseat the cables if any abnormality is found. 2 Check printer’s firmware level. Rewrite the firmware if any abnormality is found. 3 Replace the tray 3. 4 Replace the CTLB.