Code :
- Code: SC46-27#
- Description: A density conversion gamma curve cannot be created normally.
- Causes: Overall control board (OACB)
- Code: SC46-29
- Description: Calibration start abnormality
- Causes: Overall control board (OACB) OACB program
- Code: SC46-30
- Description: Calibration completion abnormality.
- Causes: Overall control board (OACB) OACB program
- Code: SC46-31
- Description: Despite of the MPC not being terminated, the initial sampling of the APC is attempted.
- Causes: Overall control board (OACB) OACB program
- Code: SC46-32
- Description: While executing the APC, the execution of the MPC is attempted.
- Causes: Overall control board (OACB) OACB program
- Code: SC46-34
- Description: When a clock for the image write is abnormal, the sub scan beam interval is attempted to be corrected.
- Causes: Overall control board (OACB) OACB program
- Code: SC46-35
- Description: Sequentially shot page area abnormality. Due to an image area abnormality on the memory, images cannot be developed on the memory.
- Causes: Overall control board (OACB) OACB program
- Code: SC46-36
- Description: The PVV is turned ON before the initial APC start processing is completed.
- Causes: Polygon motor (M17) Overall control board (OACB) OACB program Printer control board (PRCB) PRCB program