Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi Konica-Minolta bizhub 920 pro — Trang 17/32

Code: SC46-40

Description: HDD /1 (HDD1) initialization abnormality. The HDD1 is defective, or the connector is poorly connected.
Causes: Overall control board (OACB) OACB program HDD /1 (HDD1)

Code: SC46-41

Description: The JOB information cannot be stored on the HDD /1 (HDD1).
Causes: Overall control board (OACB) OACB program HDD /1 (HDD1)

Code: SC46-42

Description: When hard disk /1 (HDD1) JOB auto deletion is being executed, a route cannot be opened.
Causes: Overall control board (OACB) OACB program HDD /1 (HDD1)

Code: SC46-43

Description: HDD /1 (HDD1) access defective. The HDD1 is defective or the connector is poorly connected.
Causes: Overall control board (OACB) OACB program HDD /1 (HDD1)

Code: SC46-61#

Description: The scan operation starts before the original skew adjustment is terminated. (The skew adjustment is too late.)
Causes: DF control board (DFCB) Original skew sensor /Rr (PS311) Original skew sensor /Fr (PS312)

Code: SC46-62#

Description: The print operation starts before the paper mis-centering adjustment is terminated. (The mis-centering adjustment is too late.)
Causes: Centering sensor (PS1)

Code: SC46-63#

Description: The AGC is retried due to the decreased light volume of the exposure lamp. However, no error occurs.
Causes: Exposure lamp (L1)

Code: SC46-64#

Description: A PWM gamma curve is not created properly.
Causes: Toner control sensor board (TCSB)