  • Code: C-1259
  • Description: Bundle press stage up down motor (M24) drive abnormality. The bundle press stage up down home motor (PS35) does not turn ON even after a specified period of time after M24 starts the home position search operation. Or PS35 or the bundle press stage up down upper limit sensor (PS45) does not turned ON after a specified period of time M24 starts the operation. 34-0/1/3
  • Causes: Bundle press stage up down home sensor (PS35: SD-506) Bundle press stage up down limit sensor (PS45: SD-506) Bundle press stage up down motor (M24: SD-506) SD drive board (SDDB: SD-506) SD control board (SDCB: SD-506)
  • Remedy: 1 Check the bundle press stage up down section, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between SDDB and motor/sensor, and repair it if any abnormality. - 3 Check the connector connection and the wiring between SDDB and SDCB, and repair it if any abnormality. - 4 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. SD-506: 21-D 5 Check I/O and the operation of the sensor, and repair/replace it if any abnormality. SD-506: 24-D, 25-D 6 Replace PS35 or PS45. - 7 Replace M24. - 8 Replace SDDB. - 9 Replace SDCB.
  • Code: C-1260
  • Description: Guide shaft motor (M25) drive abnormality. The guide shaft home sensor (PS46) does not turn ON even after a specified period of time after M25 starts the home position search operation. Or, even after a specified period of time after M25 starts the operation, it does not stop. 34-0/1/3
  • Causes: Guide shaft home sensor (PS46: SD-506) Guide shaft motor (M25: SD-506) SD drive board (SDDB: SD-506) SD control board (SDCB: SD-506)
  • Remedy: 1 Check the guide shaft, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between SDDB and motor/sensor, and repair it if any abnormality. - 3 Check the connector connection and the wiring between SDDB and SDCB, and repair it if any abnormality. - 4 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. SD-506: 11-D 5 Check I/O and the operation of the sensor, and repair/replace it if any abnormality. SD-506: 15-D 6 Replace PS46. - 7 Replace M25. - 8 Replace SDDB. - 9 Replace SDCB.
  • Code: C-1261
  • Description: Stapler motor /Rt (M29) drive abnormality. Stapler home sensor /Rt (HS1) or clincher start sensor /Rt (HS2) does not turn ON even after a specified period of time after M29 starts the operation. 34-0/3
  • Causes: Stapler assy SD drive board (SDDB: SD-506) SD control board (SDCB: SD-506)
  • Remedy: 1 Check the stapler assy /Rt, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between SDDB and the stapler assy /Rt, and repair it if any abnormality. - 3 Replacing the stapler assy /Rt - 4 Replace SDDB. - 5 Replace SDCB.
  • Code: C-1262
  • Description: Stapler motor /Lt (M30) drive abnormality. Stapler home sensor /Lt (HS3) or clincher start sensor /Lt (HS4) does not turn ON even after a specified period of time after M30 starts the operation. 34-0/3
  • Causes: Stapler assy SD drive board (SDDB: SD-506) SD control board (SDCB: SD-506)
  • Remedy: 1 Check the stapler assy /Lt, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between SDDB and the stapler assy /Lt, and repair it if any abnormality. - 3 Replacing the stapler assy /Lt - 4 Replace SDDB. - 5 Replace SDCB.
  • Code: C-1263
  • Description: Trimmer blade motor (M31) drive abnormality. Or, even after a specified period of time after M31 starts the operation, it does not stop. 34-3
  • Causes: Trimmer blade home sensor (PS50: SD-506) Trimmer blade upper limit sensor (PS51: SD-506) Trimmer blade motor (M31: SD-506) SD drive board (SDDB: SD-506) SD control board (SDCB: SD-506)
  • Remedy: 1 Check the trimmer blade, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between SDDB and motor/sensor, and repair it if any abnormality. - 3 Check the connector connection and the wiring between SDDB and SDCB, and repair it if any abnormality. - 4 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. SD-506: 22-R 5 Check I/O and the operation of the sensor, and repair/replace it if any abnormality. SD-506: 23-R 6 Replace PS50 or PS51. - 7 Replace M31. - 8 Replace SDDB. - 9 Replace SDCB.
  • Code: C-1264
  • Description: Trimmer press motor (M32) drive abnormality. Or, even after a specified period of time after M32 starts the operation, it does not stop. 34-3
  • Causes: Trimmer press upper limit sensor (PS52: SD-506) Trimmer press home sensor (PS53: SD-506) Trimmer press motor (M32: SD-506) SD drive board (SDDB: SD-506) SD control board (SDCB: SD-506)
  • Remedy: 1 Check the trimmer press section, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between SDDB and motor/sensor, and repair it if any abnormality. - 3 Check the connector connection and the wiring between SDDB and SDCB, and repair it if any abnormality. - 4 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. SD-506: 22-R 5 Check I/O and the operation of the sensor, and repair/replace it if any abnormality. SD-506: 23-R 6 Replace PS52 or PS53. - 7 Replace M32. - 8 Replace SDDB. - 9 Replace SDCB.
  • Code: C-1265
  • Description: Bundle arm assist motor (M26) drive abnormality. Or, even after a specified period of time after M26 starts the operation, it does not stop. 34-0/1/3
  • Causes: Bundle arm assist home sensor (PS38: SD-506) Bundle arm assist upper limit sensor (PS39: SD- 506) Bundle arm assist motor (M26: SD-506) SD drive board (SDDB: SD-506) SD control board (SDCB: SD-506)
  • Remedy: 1 Check the bundle arm assist section, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between SDDB and motor/sensor, and repair it if any abnormality. - 3 Check the connector connection and the wiring between SDDB and SDCB, and repair it if any abnormality. - 4 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. SD-506: 16-D 5 Check I/O and the operation of the sensor, and repair/replace it if any abnormality. SD-506: 17-D 6 Replace PS38 or PS39. - 7 Replace M26. - 8 Replace SDDB. - 9 Replace SDCB.
  • Code: C-1266
  • Description: Entrance conveyance motor (M1) rotation abnormality. Rotation abnormality detected continuously for the specified time during M1 operation.
  • Causes: Entrance conveyance motor (M1: SD-506) SD drive board (SDDB: SD-506) SD control board (SDCB: SD-506)
  • Remedy: 1 Check the entrance conveyance section, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between SDDB and the motor, and repair it if any abnormality. - 3 Check the connector connection and the wiring between SDDB and SDCB, and repair it if any abnormality. - 4 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. SD-506: 2-D 5 Replace M1. - 6 Replace SDDB. - 7 Replace SDCB.