Description: Transport motor malfunction
• The motor lock signal remains HIGH for a predetermined consecutive period of time while the transport motor remains energized.
Remedy: 1 Check the M1 connector for proper connection and correct as necessary. 2 Check M1 for proper drive coupling and correct as necessary. 3 Check the PRCB connector for proper connection and correct as necessary. 4 M1 operation check PRCB PJ8-1 to 6 C-2. 5 Change M1. 6 Change PRCB. 7 Change DCPU.
Code: 001B
Description: Developing motor malfunction
• The developing motor does not rotate evenly even after the lapse of a given period of time while it is being started. • The motor lock signal remains HIGH for a given period of consecutive time while the developing motor is being rotated.
Remedy: 1 Check the developing motor connector for proper connection and correct as necessary. 2 Check the PRCB connector for proper connection and correct as necessary. 3 M3 operation check PRCB PJ5-1 to 4 C-12. 4 Change M3. 5 Change PRCB. 6 Change DCPU.
Code: 0045
Description: Exit tray cooling fan motor malfunction
Remedy: 1 Check the FM4 connector for proper connection and correct as necessary. 2 Check the fan for possible overload and correct as necessary. 3 FM4 operation check PRCB PJ24-4 (REM) PRCB PJ24-6 (LOCK) C-13. 4 Change FM4. 5 Change MFPB.
Code: 004A
Description: Duplex cooling fan motor malfunction
Remedy:
Code: 004C
Description: Ozone ventilation fan motor malfunction
• The ozone ventilation fan motor does not rotate evenly even after the lapse of a given period of time while it is being started. • The motor lock signal remains HIGH for a given period of consecutive time while the ozone ventilation fan motor is being rotated.
Remedy: 1 Check the FM2 connector for proper connection and correct as necessary. 2 Check the fan for possible overload and correct as necessary. 3 FM2 operation check PRCB PJ16-1 (REM) PRCB PJ16-3 (LOCK) C-4. 4 Change FM2. 5 Change PRCB.
Code: 004E
Description: DC power supply fan motor malfunction
• The DC power supply fan motor does not rotate evenly even after the lapse of a given period of time while it is being started. • The motor lock signal remains HIGH for a given period of consecutive time while the DC power supply fan motor is being rotated.
Remedy: 1 Check the FM1 connector for proper connection and correct as necessary. 2 Check the fan for possible overload and correct as necessary. 3 FM1 operation check HV CN2-1 (REM) HV CN2-3 (LOCK) B-4 to 5. 4 Change FM1. 5 Change PRCB.
Code: 0092
Description: Transfer belt rotation failure
• The belt positioning sensor does not detect the transfer belt position detection hole a second time even after the lapse of a predetermined period of time after it has detected one while the transfer belt is rotated.
Remedy: 1 Check the PRCB connector for proper connection and correct as necessary. 2 PS6 sensor check. 3 Change imaging cartridge. 4 Change PRCB.
Code: 0094
Description: 2nd image transfer pressure / retraction failure
• The 2nd image transfer retraction position sensor is not activated (retracted position) within a given period of time after the retraction sequence of the 2nd transfer roller has been started. • The 2nd image transfer retraction position sensor is not deactivated (pressed position) within a given period of time after the pressure sequence of the 2nd transfer roller has been started.
Remedy: 1 Check the M1 connector for proper connection and correct as necessary. 2 Check the SD4 connector for proper connection and correct as necessary. 3 Check M1 for proper drive coupling and correct as necessary. 4 Check SD4 for proper drive coupling and correct as necessary. 5 Check the PRCB connector for proper connection and correct as necessary. 6 PS3 sensor check PRCB PJ12-3 (ON) C-2. 7 SD4 operation check PRCB PJ10-6 (REM) C-9. 8 M1 operation check PRCB PJ8-1 to 6 C-2. 9 Change M1. 10 Change SD4. 11 Change PRCB.