Các lỗi thường gặp

Code :
  • Code: 065
  • Display: Service call
    065: Error
  • Description: NIC Combination Error
  • Remedy: Replace 86M board
  • Code: 066
  • Display: Service call
    066: Error
  • Description: FAX Combination Error
  • Remedy: Is FX-5 board used? No use FX-5 board.
  • Code: 070
  • Display: Service call
    070: Error
  • Description: PostScript Internal Error
  • Remedy: Is the error message displayed again? Yes Power supply Off/On Replace 86M board
  • Code: 072
  • Display: Service call
    072: Error
  • Description: Engine I/F Error I/F Error between PU and CU
  • Remedy: Replace 86M board
  • Code: 073
  • Display: Service call
    073: Error
  • Description: Video Error When the image data sprads, defect is detected. (Incorrect data receive)
  • Remedy: Does the error recur? Yes Change the PC to high spec or lower the resolution, and then print again. Replace 86M boar
  • Code: 074, 075
  • Display: Service call
    074: Error
    075: Error
  • Description: Video Error When the image data spreads, defect is detected.
  • Remedy: Replace 86M board
  • Code: 081
  • Display: Service call
    081: Error
  • Description: Difference between version of CU firm and EEPROM
  • Remedy: Does the error recur? Yes Do EEPROM Initialization. (Turn on the power supply by Cover-open & pressing START key & pressing CANCEL switch). Because the Mac address will disappear with this initialization, lease reset Mac address by using the maintenance utility. Replace 86M board
  • Code: 104
  • Display: Service call
    104: Error
  • Description: EngineEEPROM mounting check is OK with turning on the power supply, after that, lead/light error is detected
  • Remedy: Does the error recur? Yes Power supply Off/On Replace 86M board