Description: The short circuit of the backup roller. Thermistor is detected. (For the high temperature)
Remedy:
Code: 175
Display: Service call 175: Error
Description: The open circuit of the backup roller. Thermistor is detected. (For the low temperature)
Remedy:
Code: 176, 177
Display: Service call 176: Error 177: Error
Description: Temperature abnormality (high or low) of the backup roller thermistor was detected
Remedy:
Code: 182
Display: Service call 182: Error
Description: Tray2 Unit I/F Error
Remedy: Is the Second Tray unit used? • Yes Is the printer main body appropriately set on the Second Tray unit? • No Set the printer main body appropriately. • Yes Replace the main board. • Has the trouble been solved? • No Check the trouble according to the maintenance manual of the Second Tray unit of the appendix C. • Yes Completed. • No Replace the main board.
Code: 190
Display: Service call 190: Error
Description: System memory overflow
Remedy: Does the error recur? Yes Turn on the power supply again. Install an additional RAM DIMM.
Code: 200, 201, 202
Display: Service call 200: Error 201: Error 202: Error
Description: PU Firmware Download Error Error occurs when the PU firmware is rewritten
Remedy: Error occurs when the PU firmware is rewritten After the power supply is turned on again, try to download again. (Because this processing is not performed during usual operation, it does not occur.)
Description: CU program trouble (203~214 are not generated in usual operation)
Remedy: Incorrect processing is performed by the CU program. Does the error recur? Turn on the power supply again. Replace 86M board.
Code: 209
Display: Service call 209: Down Load Error
Description: Custom Media Type table download failure Failed in downloarding Custom Media Type Table
Remedy: Failed in downloarding Custom Media Type Table After the power supply is turned on again, try to download again. (Because this processing is not performed during usual operation, it does not occur.)