Remedy: Is RAM DIMM mounted normally? Does it restore by exchanging RAM DIMM? Remount RAM DIMM Replace RAM DIMM Replace 86M board
Code: 034
Display: Service call 034: Error
Description: RAM Configuration Error
Remedy: RAM Configuration Error
Code: 040
Display: Service call 040: Error
Description: CU EEPROM Error
Remedy: Is the error message displayed again? Power supply Off/On Replace 86M board
Code: 041
Display: Service call 041:Error
Description: CU Flash Error Flash ROM Error on the CU board
Remedy: Is the error message displayed again? Yes Power supply Off/On Replace 86M board
Code: 042, 043
Display: Service call 042: Error 043: Error
Description: Flash File System Error It failed to the access to CU Flash ROM that is attached to the 86M board directly.
Remedy: It failed to the access to CU Flash ROM that is attached to the 86M board directly. The compulsive initialization of Flash is done. (Because NICFirmware is deleted, please be careful to it. After initialization, it is necessary to write NIC-Firmware by the maintenance utility).FLASH FORMAT is executed by using the maintenance utility.If the symptom doesn't change, replace the 86M board.
Code: 045
Display: Service call 045: Error
Description: Flash File System Recovery Failed
Remedy: Is the error message displayed again? Yes Power supply Off/On Replace 86M board
Code: 048
Display: Service call 048: Error
Description: PS Protection A PS ROM was installed in the Non-PS device. In MB470/MB480, the same error can occur when the LED Head is missing. Is the LED Head connected properly?
Remedy: A PS ROM was installed in the Non-PS device. In MB470/MB480, the same error can occur when the LED Head is missing. Is the LED Head connected properly? Replace 86M board Reconnect correctry Replace 86M board
Code: 063
Display: Service call 063: Error
Description: PCI Driver Open error
Remedy: Is the error message displayed again? Yes Power supply Off/On Replace 86M board