Mã lỗi Ricoh Aficio 3025 — Trang 8/17

Code: 611

Description: Communication break error between SBCU and ADF
The SBCU received a break (LOW) signal from the ADF main board.
Causes: • Serial line connecting SBCU and ADF unstable • Connectors between SBCU and ADF loose, disconnected, or damaged

Code: 612

Description: Communication command error between SBCU and ADF
Causes: • Update the firmware • SBCU board defective

Code: 620

Description: Communication timeout between SBCU and finisher: Error 1
The SBCU cannot receive a response within 100 ms after 3 attempts after sending data to the finisher.
Causes: • Serial line connecting SBCU and finisher unstable • External noise

Code: 621

Description: Communication timeout between SBCU and finisher: Error 2
A break (LOW) signal was received from the finisher.
Causes: • Serial line connecting SBCU and finisher unstable • External noise

Code: 650

Description: Communication timeout error between SBCU and duplex unit
The SBCU cannot receive a response within 1 sec. from the duplex unit.
Causes: • Serial line connecting SBCU and duplex unit unstable • External noise • SBCU board and duplex main board connection defective or loose • Duplex main board defective • SBCU board defective

Code: 669

Description: EEPROM Communication Error
The machine failed to detect a match between the read/write data for the EEPROM on the SBCU after 3 attempts.
Causes: • EEPROM installed incorrectly • EEPROM defective After you check the installation, turn the machine off and on. If this does not repair the problem, replace the SBCU.

Code: 670

Description: Engine response error
After powering on the machine, a response is not received from the engine within 30 seconds.
Causes: • SBCU installed incorrectly • SBCU defective • Controller board defective

Code: 672

Description: Controller-to-operation panel communication error at startup
After powering on the machine, the communication circuit between the controller and the operation panel is not opened, or communication with controller is interrupted after a normal startup.
Causes: • Controller stall • Controller board installed incorrectly • Controller board defective • Operation panel connector loose or defective