Description: Charge corona output error
Charge corona feedback voltage of less than 1V was detected for more than 200 s.
Causes: • CBG power pack is defective. • High voltage cable is defective. • Poor connection of the power pack connector. • Dirty charge corona unit caused leakage.
Description: Charge grid output error
Control PWM duty value is higher than 1% (FB less than 1V) for more than 200 ms (a grid current leak).
Causes: • CBG power pack is defective. • High voltage cable is defective. • Poor connection of the power pack connector. • Dirty charge corona unit causing leakage
Description: Charge corona wire cleaner error
Wire cleaner motor feedback voltage of less than 0.1 V was detected for more than 1s. Corona wire cleaning did not complete within 80 s. Charge wire cleaner did not return to the home position. Cleaner does not move from the home position.
Causes: • Wire cleaner motor connector disconnected. • Wire cleaner motor connector disconnected. • Wire cleaner motor is operating without load. • Wire cleaner stops due to an overload. • Wire cleaner motor drive circuit malfunction.
Description: Development bias error
A development bias feedback voltage of less than 0.25V was detected for more than 200 ms while the PWM duty value was more than 1% (development bias leak).
Causes: • Possible Cause • CBG power pack defective • Bias cable defective • Poor bias cable connection • Bias leak