Các lỗi thường gặp

Code :
  • Code: SC541
  • Description: Fusing thermistor open
    The fusing temperature detected by the thermistor was below 13C (55.4F) 60 times within one 1 s.
  • Causes: • Fusing thermistor defective • Thermistor cable disconnected, broken
  • Code: SC542
  • Description: Fusing temperature warm-up error
    After switching on the machine, or after opening and closing the machine, during warmup the hot roller did not attain the ready temperature within 5 minutes (the temperature was detected below 2C 5 times within 5 s).
  • Causes: • Fusing lamp defective • Fusing thermistor defective • Thermistor floating, out of position • Thermistor cable disconnected, broken
  • Code: SC543
  • Description: Fusing overheat error 1 (software)
    A fusing temperature of over 215 C (419F) was detected for 5 s
  • Causes: • IOB board defective • BCU board defective • PSU defective • TRIAC short
  • Code: SC544
  • Description: Fusing overheat error 2 (hardware)
    The BCU backup circuit detects an overheat error even if the software overheat protection does not work.
  • Causes: • TRIAC short • IOB board defective • BCU board defective • PSU board defective
  • Code: SC545
  • Description: Fusing lamp overheat error 3
    After reaching the ready temperature, the hot roller does not start to rotate and the fusing lamp stays on at full power for 60 s.
  • Causes: • Hot roller thermistor not positioned correctly • Fusing lamp defective • Thermostat defective
  • Code: SC546
  • Description: Unstable fusing temperature
    Fusing temperature is rapidly fluctuating more than 20°C (68°F) at 1 s intervals. -or-Fusing temperature fluctuating over a long period. It fluctuates 20°C (68°F) more than 3 times during 60 s interval.
  • Causes: • Poor thermistor connection
  • Code: SC547
  • Description: Zero-cross signal malfunction
    One of the following conditions has occurred: • Abnormal mains frequency was detected more than 10 times. • No zero-cross signal detected for 3 s while the relay is on. • No zero-cross signal detected for 3.5 s after the main switch is turned on.
  • Causes: • Electrical noise on the power line. • PSU defective.
  • Code: SC549
  • Description: Pressure roller thermistor abnormal
    During fusing motor rotation, pressure roller temperature detected lower than 7°C (44.6°F) for 5 s.
  • Causes: • Thermistor shorted, disconnected, or its connector is damaged.