Code :
  • Code: SC351
  • Description: ID sensor error 2 - Vsg
    Vsg is 0V or more than 2.5 V. During the copy cycle, this SC is displayed after the copy is executed.
  • Causes: • ID sensor defective • ID sensor connector defective • IOB malfunction • CBG power pack defective • Dirty ID sensor • VDB defective • LPH defective
  • Code: SC352
  • Description: ID sensor error 3 - Pattern
    Pattern voltage less was less than 2.5 V and cannot be detected. During the copy cycle, this SC is displayed after the copy is executed.
  • Causes: • Possible Cause • ID sensor defective • ID sensor connector defective • IOB malfunction • CBG power pack defective • Dirty ID sensor • VDB defective • LPH defective
  • Code: SC353
  • Description: ID sensor error 4 - LED
    LED drive current (PWM value) is 255 or 0. This SC could occur while the ID sensor is initializing.
  • Causes: • Possible Cause • ID sensor defective • ID sensor connector defective • IOB malfunction • CBG power pack defective • Dirty ID sensor • VDB defective • LPH defective
  • Code: SC354
  • Description: ID sensor error 5 - Timeout
    Vsg cannot be adjusted to 4 ±0.2V within 20 s. This SC could occur while the ID sensor is initializing.
  • Causes: • ID sensor defective • ID sensor connector defective • IOB malfunction • CBG power pack defective • Dirty ID sensor • VDB defective • LPH defective
  • Code: SC401
  • Description: Transfer corona leak error
    A transfer corona feedback voltage of less than 0.25V was detected for more than 200 ms.
  • Causes: • T&S power pack defective. • Transfer corona cable defective. • Poor transfer corona cable connection. • Dirty T&S corona unit caused leak
  • Code: SC411
  • Description: DC separation corona current leak
    A dc separation feedback voltage of less than 0.5V was detected after more than 200 ms while the PWM duty value was more than 17%.
  • Causes: • T&S power pack defective. • Transfer corona cable defective. • Paper separation current cable defective. • Poor paper separation current cable connection.
  • Code: SC440
  • Description: Drum drive motor lock
    The motor lock signal is on longer than 5 s while the drum drive motor is on.
  • Causes: • Drive mechanism overload. • Motor defective.
  • Code: SC503
  • Description: Cassette Tray 1 3 feed error
    After the tray was closed, the lift sensor in Tray 3 did not switch on within 20 s after the tray lift motor switched on. -or-The lift sensor did not switch off within 1 s four times after the tray started to descend.
  • Causes: • Lift motor connector loose, disconnected, broken. • Paper or other foreign object has jammed the tray lift motor. • Pickup solenoid connector is loose, disconnected, damaged. • An obstruction in the mechanical operation of the pickup solenoid • Replace the tray lift sensor.