Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi Ricoh Aficio 480W — Trang 7/12

Code: SC821

Description: Self-diagnostic error 2: ASIC
The ASIC provides the central point for the control of bus arbitration for CPU access, for option bus and SDRAM access, for SDRAM refresh, and for management of the internal bus gate
Causes: • ASIC defective, replace the controller board • ASCI timing device defective, or CPU defective. Replace the controller board.

Code: SC822

Description: Self-diagnostic error 3: HDD
Causes: • HDD defective • HDD harness disconnected, defective • Controller board defective

Code: SC823

Description: Self-diagnostic error 4: NIC
Causes: • If the optional NIC is detected, replace it. • Replace the controller board. • Check the interface connection between the NIC and the controller board. • Replace the NIC board. • Replace the controller board.

Code: SC824

Description: Self-diagnostic error 5: NVRAM
Causes: • NVRAM defective • Controller board defective • NVRAM backup battery exhausted • NVRAM socket damaged

Code: SC826

Description: Self-diagnostic error 6: NVRAM (RTC/option NVRAM)
Causes: • NVRAM defective • NVRAM installed incorrectly • Replace RTC device

Code: SC827

Description: Self-diagnostic error 7: RAM
Causes: • Replace the RAM DIMM. • Replace the controller board

Code: SC828

Description: Self-diagnostic error 8: ROM
Causes: • Update (upload again) all firmware modules to restore the boot program and the self-diagnostics. • Replace the controller board. • Software defective • Controller board defective • ROM defective

Code: SC829

Description: Self-diagnostic error 9: Optional RAM
Causes: • Change the controller board or the optional RAM DIMM