Các lỗi thường gặp

Code :
  • Code: SC633
  • Description: Key/card counter device error 2
    During communication with the device, the BCU received a break (Low) signal.
  • Causes: • The serial line from the device to the copier is unstable, disconnected, or defective.
  • Code: SC634
  • Description: Key/card counter device error 3
    The backup battery of the counter device RAM is low.
  • Causes: • Replace the RAM backup battery.
  • Code: SC635
  • Description: Key/card counter device error 4
    After installation of the device a message alerts user to a battery voltage abnormal error.
  • Causes: • Device control board defective • Device control board backup battery defective
  • Code: SC670
  • Description: Engine startup error
    The BCU failed to respond with the prescribed time when the machine was turned on.
  • Causes: • Connections between BCU and controller board are loose, disconnected, or damaged • Replace the BCU • Replace the controller board
  • Code: SC672
  • Description: Controller startup error
    • After power on, the line between the controller and the operation panel did not open for normal operation. • After normal startup, communication with the controller stopped.
  • Causes: • Controller stalled • Controller installed incorrectly • Controller board defective • Operation panel harness disconnected or defective
  • Code: SC818
  • Description: Watchdog error
    While the system program is running, a bus hold or interrupt program goes into an endless loop, preventing any other programs from executing.
  • Causes: • System program defective; switch off/on, or change the controller firmware if the problem cannot be solved • Controller board defective • Replace peripheral device
  • Code: SC819
  • Description: Fatal kernel error
    Due to a control error, a RAM overflow occurred during system processing. One of the following messages was displayed on the operation panel.
  • Causes: • System program defective • Controller board defective • Optional board defective • Replace controller firmware
  • Code: SC820
  • Description: Sellf-diagnostic error 1: CPU
    An unexpected error occurred, or the boot monitor program or self-diagnostic program generated an interrupt. In either case, this is a fatal error.
  • Causes: • Replace the controller board • Update (upload again) all firmware modules to restore the boot program and the self-diagnostics.