Description: Communication error of the remote service modem (Cumin-M): Authentication error
The authentication for the Embedded RCG-M fails at a dial up connection.
Causes: 1. Check and set the correct user name (SP5816-156) and password (SP5816-157).
Description: Communication error of the remote service modem (Cumin-M): Communication line error
The supplied voltage is not sufficient due to the defective communication line or defective connection.
Causes: 1. Consult with the user's local telephone company.
Description: Engine startup error
Just after the main power is turned on or the machine is recovering from auto off mode, the engine ready signal assertion fails. Just after the main power is turned on, the engine does not respond.
Causes: • Poor connection between the BICU and controller board
• Defective BICU
• Defective controller board
Description: Controller-to-operation panel communication error at startup
After powering on the machine, communication between the controller and operation panel does not begin, or the communication is interrupted after a normal startup.
Causes: • Controller stalled • Controller board installed incorrectly
• Defective controller board
• Operation panel connector loose or defective
• Poor connection of DIMM and optional boards on the controller board 1. Check the setting of SP5875-001. If the setting is set to "1 (OFF)", change it to "0 (ON)".