Description: Over the number of the banks installed error
Receiving a code other than the following cord: For Model S-C5: 01H 02H
Causes: • More than 3 of the banks are installed. (Specific limitation for Model S-C5 is 2 at maximum)
Code: 817
Description: Monitor Error
This is a file detection and electronic file signature check error when the boot loader attempts to read the selfdiagnostic module, system kernel, or root system files from the OS Flash ROM, or the items on the SD card in the controller slot are false or corrupted.
Causes: • OS Flash ROM data defective; change the controller firmware
• SD card data defective; use another SD card
Code: 818
Description: Firmware update error
This error may occur while firmware update.
Causes: 1. Reboot the copier and complete the undone update.
Code: 819
Description: Kernel stop
Due to a control error, a RAM overflow occurred during system processing. One of the following messages was displayed on the operation panel.
Causes: • System program defective
• Controller board defective
• Optional board defective
1. Replace controller firmware
Code: 820
Description: Self-Diagnostic Error: CPU
During the boot monitor program and self-diagnostic, any exception or cutin are not supposed to happen. If these happen, it is defined as SC.
Causes: • Defective CPU device
• Defective boot monitor program or selfdiagnostic program
Description: Self-diagnostic error: HDD (Hard Disk Drive)
When the main switch is turned on or starting the self-diagnostic, the HDD stays busy for the specified time or more.