Description: Over zero cross frequency
The number of times Low-frequency wave detection is less than 1 time.
Causes: • Interruption of power source line noise.
Code: 559
Description: Consecutive fusing jam
The paper jam counter for the fusing unit reaches 3 times. The paper jam counter is cleared if the paper is fed correctly. This SC is activated only when SP1159-001 is set to "1" (default "0").
Causes: • Paper jam in the fusing unit.
Code: 620
Description: ADF communication error
Disconnection after connection in normal.
Causes: • Defective the ADF
• Defective the IPU board
• Bad connection of the ADF
Code: 622
Description: Bank communication error
1. Malfunction occurs on line connection.
2. Receiving a communication error notice from the URAT.
Causes: • Defective the bank control board
• Defective the BICU, the IOB
• Bad connection between the bank and the main machine
• Defective the bank control
Code: 623
Description: Second bank communication error
Abnormal code is send from the bank unit.
Causes: • Bad connection between the first bank and the second bank
• Defective the bank control board
• NOT all connectors are in place
Code: 632
Description: MF accounting device error 1
The machine sends a data frame. No normal end signal returns. This symptom happens three times.
Causes: • Defective or broken line between machine and device
Code: 633
Description: MF accounting device error 2
The machine is communicating with the accounting device. The break signal returns.
Causes: Defective or broken line between machine and device
Code: 634
Description: MF accounting device error 3
A backup RAM error is reported from the accounting device.
Causes: • Defective accounting device controller
• Defective battery in the accounting device