Các lỗi thường gặp

Code :
  • Code: 542-001
  • Description: Fusing reload failed: Fusing temperature warm-up error
    • The fusing temperature doesn’t rise by more than 7 degrees for two seconds; and this happens 5 times consecutively.
    The measure is start in 3.5 seconds after activation of the heater. This monitoring will stop in the case of reaching the reload temperature.
  • Causes: • Defective thermistor
    • Power source is out of warranty
  • Code: 542-003
  • Description: Fusing reload failed: Time out error
    (On the fusing roller inactive) NOT reaching the reload temperature in 25 seconds after starting heater control.
  • Causes: • Disconnection of Heater After activation of the anti-overheat device
  • Code: 543
  • Description: Fusing overheat error 1
    The fusing temperature detected by the thermistor is 230°C or higher for one second.
  • Causes: • Defective the triac (Semiconductor device) • Defective the IOB control board
    • Detective the BICU control board
  • Code: 544
  • Description: Fusing overheat error 2
    The fusing temperature detected by the monitor circuit is 250°C or higher.
  • Causes: • Defective the triac (Semiconductor device)
    • Defective the IOB control board
    • Defective the BICU control board
    • Uncontrollable fusing condition
  • Code: 545
  • Description: Fusing lamp overheat error
    The fusing lamp remains on for 12 seconds after starting the waiting mode.
  • Causes: • Defective thermistor
    • Disconnection of Heater
    • After activation of the anti-overheat device
  • Code: 547-001
  • Description: Zero cross signal malfunction
    Detecting fusing contact meltdown
  • Causes: • Defective the fusing relay (Contact adhesion, Contact separation)
    • Defective the drive circuit in the fusing relay
    • PSU fuse (24VS) meltdown
    • Unsteadiness in frequency of the commercial power source
  • Code: 547-002
  • Description: Zero cross signal malfunction
    Detecting wrong with fusing contact
  • Causes: • Defective the fusing relay (Contact adhesion, Contact separation)
    • Defective the drive circuit in the fusing relay
    • PSU fuse (24VS) meltdown
    • Unsteadiness in frequency of the commercial power source
  • Code: 547-003
  • Description: Zero cross signal malfunction
    Detecting low-frequency wave
  • Causes: • Defective the fusing relay (Contact adhesion, Contact separation)
    • Defective the drive circuit in the fusing relay
    • PSU fuse (24VS) meltdown
    • Unsteadiness in frequency of the commercial power source