Code: 635

Description: MF accounting device error 4
A battery voltage error is reported from the accounting device.
Causes: • Defective accounting device controller
• Defective battery in the accounting device

Code: 636-001

Description: SD Card Error: Expanded authentication module error
There is no expanded authentication module in the machine. The SD card or the file of the expanded authentication module is broken. There is no DESS module in the machine.
Causes: 1. Install the correct SD card or the file of the expanded authentication module.
2. Install the DESS module.

Code: 636-002

Description: SD Card Error:Version error
The version of the expanded authentication module is not correct.
Causes: 1. Install the correct file of the expanded authentication module.

Code: 636-011

Description: SD Card Error: OSM usercode file error
NOT found the "usercode" file in the rootfolder, in the SD card Or cannot read the usercode file correctly. *This SC occurs only for OSM IC card.
Causes: • No usercode file exists in the SD card • Irregular usercode file • The data in the usercode file is irregular • NOT coping the application with the "usercode" file to the SD card. 1. Make a customer usercode by the OSM usercode setting tool (IDissuer.exe) and put it in the rootfolder where IC card module (eccm.mod) is stored.

Code: 637-001

Description: Tracking APP error: NOT found the tracking information
Causes: • Causes of failing to notice tracking SDK APP (e.g.: Defective tracking SDK APP, Abnormal internal communication)
1. Power source OFF/ON

Code: 637-002

Description: Tracking APP error: Administration server error
NOT found the tracking information.
Causes: • Defective tracking administration server
• Defective tracking SDK APP
• Defective Network
1. Power source OFF/ON

Code: 640

Description: Engine to controller communication error (Check Sum error)
Incorrect sum data.
Causes: • Defective the PCI related hardware

Code: 641

Description: Engine to controller communication error (No response)
No response to the frame from the engine when frame sending according to RAPI protocol is done from the controller.
Causes: