Description: ID sensor error 5 Vsg falls out of the adjustment target (4.0 ±0.2V) during Vsg checking.
Causes: • ID sensor defective • ID sensor harness disconnected • ID sensor connector defective • IOB defective • ID sensor pattern not written correctly • Incorrect image density • Charge power pack defective • ID sensor dirty
Remedy:
Code: 355
Description: ID sensor error 6 The Vp value, which measures the reflectivity of the ID sensor pattern, was not in the range of -70V to -400V.
Description: Transfer output abnormal When the transfer is output, the feedback voltage remains higher than 4V for 60 ms.
Causes: • Transfer power pack defective • Transfer current terminal, transfer power pack disconnected, damaged connector
Remedy:
Code: 402
Description: Transfer output abnormal release detection When the transfer is output, there is hardly any feedback voltage within 60 ms even with application of 24% PWM.
Causes: • Transfer power pack defective • Transfer unit harness disconnected • Transfer connector loose, defective
Remedy:
Code: 430
Description: Quenching lamp error At the completion of auto process control initialization, the potential of the drum surface detected by the potential sensor is more than -400V, the prescribed value.