Code: 544

Description: Fusing lamp overheat error 1 (hardware)
The center thermistor or an end thermistor detected a temperature of 250°C on the hot roller.
Causes: • PSU defective • IOB defective • BICU defective
Remedy:

Code: 545

Description: Fusing lamp overheat error 2
After hot roller reaches warmup temperature, the fusing lamps remained on at full capacity for 11 samplings (1.8 s. duration) while the hot roller was not rotating.
Causes: • Thermistor damaged, or out of position • Fusing lamp disconnected
Remedy:

Code: 547

Description: Zero cross signal malfunction
One of the following conditions is detected 10 times: • When the main switch is on, the frequency measured by the number of zero cross signals for 500 ms is larger than 66Hz or smaller than 45 Hz. • The interval between one zero cross signal and the next is 7.5 ms or shorter 3 times consecutively for 500 ms.
Causes: • Noise on the ac power line
Remedy:

Code: 551

Description: Fusing thermistor error 1
The end thermistor (contact type) was less than 0C (32F) for more than 7 seconds.
Causes: • Thermistor disconnected • Thermistor connector defective
Remedy:

Code: 552

Description: Fusing thermistor error 2
The end thermistor (contact type) could not detect: • 100°C 25 seconds after the start of the warmup cycle. • A change in temperature more than than 16 degrees for 5 seconds. • The reload temperature with 56 seconds after the start of the fusing temperature control cycle.
Causes: • Fusing lamp disconnected • Thermistor bent, damaged • Thermistor position incorrect
Remedy:

Code: 553

Description: Fusing thermistor error 3
The end thermistor (contact type) was at 240°C (464°F) for more than 1 second. The temperature is read 10 times every second. (at 0.1 s intervals).
Causes: • PSU defective • IOB control board defective • BICU control board defective
Remedy:

Code: 555

Description: Fusing lamp error
After the start of the warmup cycle, a fusing lamp was at full power for 1.8 s but the hot roller did not turn.
Causes: • Thermistor bent, out of position • Fusing lamp disconnected • Circuit breaker opened
Remedy:

Code: 557

Description: Zero cross signal error
High frequency noise was detected on the powe r line.
Causes: • No action required. The SC code is logged and the operation of the machine is not affected.
Remedy: