Description: Engine is down when machine starts up (SC reboot can not be performed) (* See “When SC670 Is Displayed” below). Machine-down was detected after the /ENGRDY signal was not asserted.
Causes: The engine board was reset at an unexpected time
Remedy: Check the connection between the engine board and the controller board. • If it is always reproduced, replace the engine board. If the problem persists, consider replacing the controller board or other boards between them. • If reproducibility is low, multiple causes are to be considered, such as software, engine board, controller board, and PSU.
Code: 672-00
Description: Controller start up error After the machine was powered on, communication between the controller and the operation panel was not established.
Remedy: • Cycle the main power off and on. • Check the connection of the controller board. • Replace the controller board. • Check the control panel harness.
Code: 672-10
Description: Controller start up error After the machine was powered on, communication between the controller and the operation panel was not established.
Remedy: • Cycle the main power off and on. • Check the connection of the controller board. • Replace the controller board. • Check the control panel harness.
Code: 672-11
Description: Controller start up error After the machine was powered on, communication between the controller and the operation panel was not established, or communication with controller was interrupted after a normal startup.
Remedy: • Cycle the main power off and on. • Check the connection of the controller board. • Replace the controller board. • Check the control panel harness. • Make sure that only DIP switch number 3 is ON.
Code: 672-12
Description: Controller start up error Communication with controller was interrupted after a normal startup.
Remedy: • Cycle the main power off and on. • Check the connection of the controller board. • Replace the controller board. • Check the control panel harness.
Code: 672-13
Description: Controller start up error The operation panel detects that the controller is down due to other reason shown in SC672-10, SC672-11, and SC672-12.
Remedy: • Cycle the main power off and on. • Check the connection of the controller board. • Replace the controller board. • Check the control panel harness.
Code: 672-99
Description: Controller start up error The operation panel software ended abnormally.
Description: Operation panel Flair communication error (Smart Operation Panel) This SC is issued only for the machine that has the Smart Operation Panel installed. • Communication between Smart Operation Panel and main machine (this is called “Flair communication”) is not sent to Smart Operation Panel. • SP setting (SP5-748-201) for Smart Operation Panel is not activated.
Causes: The CATS module (controller) did not see the response to notification of monitoring service module (operation panel)
Remedy: • Cycle the main power off and on. • Set SP5-748-201 to “1: Connect” if the value is “0: Not connect”