Các lỗi thường gặp

Code :
  • Code: SC637-01
  • Description: Tracking information notification error. Ttracking application error
  • Causes: Tracking information was lost. The machine failed to give notice of the tracking information to the tracking SDK application.
  • Remedy: •X Cycle the machine off/on
  • Code: SC637-02
  • Description: Tracking information notification error. Management server error
  • Causes: The machine failed to give notice of the tracking information to the management server. Tracking information was lost, and the machine could not count correctly.
  • Remedy: •X Cycle the machine off/on
  • Code: SC640
  • Description: Engine-to-Controller Communication Error CTL This is a checksum error.
  • Causes: •X PCI hardware error
  • Remedy: •X Cycle the machine off/on
  • Code: SC641
  • Description: Engine serial communication error CTL An error occurs in serial communication with engine.
  • Causes: •X SC641-1: Timeout error •X SC641-2: Retry over •X SC641-3: Download error •X SC641-4: UART error
  • Remedy: •X Cycle the machine off/on
  • Code: SC650-01
  • Description: @Remote communication error (Cumin-M)
  • Causes: The authentication for the Cumin-M fails failed at a dial up connection due to one or more of the following: •X Incorrect SP settings •X Disconnected telephone line •X Disconnected modem board •X Disconnected wireless LAN card
  • Remedy: •X Check and set the correct user name (SP5-816-156) and password (SP5-816-157).
  • Code: SC650-04
  • Description: @Remote communication error (Cumin-M) Communication line error The supplied voltage is not sufficient due to the defective communication line or defective connection.
  • Causes: The authentication for the Cumin-M fails failed at a dial up connection due to one or more of the following: •X Incorrect SP settings •X Disconnected telephone line •X Disconnected modem board •X Disconnected wireless LAN card
  • Remedy: •X Check and set the correct user name (SP5-816-156) and password (SP5-816-157).
  • Code: SC650-05
  • Description: @Remote communication error (Cumin-M) No modem board Modem board is not installed even though the setting at Cumin-M (During the operation)
  • Causes: The authentication for the Cumin-M fails failed at a dial up connection due to one or more of the following: •X Incorrect SP settings •X Disconnected telephone line •X Disconnected modem board •X Disconnected wireless LAN card
  • Remedy: •X Check and set the correct user name (SP5-816-156) and password (SP5-816-157).
  • Code: SC650-13
  • Description: @Remote communication error (Cumin-M) Modem board error 1
  • Causes: Modem board not installed or the board is defective.
  • Remedy: •X Install the modem board. •X Check correct setting value for modem driver (SP5-816-160, SP5-816-165 to 171, SP5-816-188 and 189). •X Replace the modem board.