Description: IPU Error 2: Ri2005 SIB Response Error. At power on, or when the machine returned from energy save mode, an IPU error occurred because Ri did not respond within 5 ms.
Description: IPU Error 3: Ri2005 S-to-M Response Error At power on, or when the machine returned from energy save mode, the Ri2005 chip on the IPU did not respond within 5 ms.
Description: IPU Error: Ri2005 M-to-P Response Error. At power on, or when the machine returned from energy save mode, the Ri2005 chip on the IPU did not respond within 5 ms.
Description: IPU Error 1: Volans Configuration Error At power on, or when the machine returned from energy save mode, FPGA (flash program) did not configure correctly within 500 ms, or an FPGA communication check failed.
Causes: •X Check all harness connections to the IPU for a loose, broken, defective connection •X IPU defective
Description: Illegal Copy Prevention Function Error The illegal copy prevention function failed to initialize at power on, or when the machine returned from the energy save mode, because the ICIB3 board was not detected or was not installed correctly. Note: The ICIB3 (option) is the PCB installed on the back of the machine that controls the function that prohibits illegal copying of currency, bank notes, etc.
Causes: •X Check installation and connection of the ICIB3 board •X ICIB3 defective
Remedy:
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.