Các lỗi thường gặp

Code :
  • Code: SC650-14
  • Description: @Remote communication error (Cumin-M) Modem board error 2
  • Causes: Modem board not installed or the board is defective.
  • Remedy: •X Uninstall the modem board if it is installed. •X Check that the wired/wireless LAN is working properly.
  • Code: SC651-01
  • Description: Incorrect dial up connection. Chat program parameter error. An unexpected error occurs when the modem (Cumin-M) tries to call the center with a dial up connection.
  • Causes: •X Caused by a software bug
  • Remedy: •X No action required •X This SC does not interfere with operation of the machine.
  • Code: SC651-02
  • Description: Incorrect dial up connection. Chat program execution error. An unexpected error occurs when the modem (Cumin-M) tries to call the center with a dial up connection.
  • Causes: •X Caused by a software bug
  • Remedy: •X No action required •X This SC does not interfere with operation of the machine.
  • Code: SC652
  • Description: Remote service ID2 mismatching There was an authentication mismatch between ID2 for @Remote, the controller board, and NVRAM.
  • Causes: •X Used controller board installed •X Used NVRAM installed •X An unexpected error occurs when the modem (Embedded RCG-M) tries to call the center with a dial up connection.
  • Remedy: •X Install the correct controller board or anew controller board. •X Install the correct NVRAM or new NVRAM.
  • Code: SC653
  • Description: Incorrect remote service ID2 CTL ID2 stored in the NVRAM is incorrect.
  • Causes: •X Used NVRAM installed •X An unexpected error occured when the modem (Embedded RCG-M) tries to call the center with a dial up connection
  • Remedy: •X Clear the ID2 in the NVRAM •X Input the correct ID2.
  • Code: SC669
  • Description: EEPROM Communication Error Five attempts to communicate between the EEPROM and NVRAM failed.
  • Causes: •X Device ID data corrupted •X Connection between controller board and MCU loose, broken, defective •X NVRAM defective •X Controller board defective •X MCU defective
  • Remedy:
  • Code: SC670
  • Description: Engine startup error CTL The MCU failed to respond within the prescribed time when the machine was turned on.
  • Causes: •X Connections between MCU and controller board are loose, disconnected, or damaged •X MCU defective •X Controller board defective
  • Remedy:
  • Code: SC672
  • Description: Controller start up error CTL •X After the machine was powered on, communication between the controller and the operation panel was not established, or communication with controller was interrupted after a normal startup. •X After startup reset of the operation panel, the attention code (FDH) or the attention acknowledge code (FEH) was not sent from the controller within 30 sec.. •X After the controller issued a command to check the communication line with the controller at 30-second intervals, the controller failed to respond twice.
  • Causes: •X Controller stalled •X Controller board installed incorrectly •X Controller board defective •X Operation panel connector loose, broken, or defective •X The controller did not completely shut down when the switch was turned off.
  • Remedy: •X Check the setting of SP5-875-001. •X If this SP is set to "1 (OFF)", change it to "0 (ON)"