Description: Polygon motor error 3: Laser Unit YM The polygon motor stops operating while the LD units of the laser unit CK are firing.
Causes: • Harness to the IPU disconnected • Harness inside the laser unit YM disconnected • Polygon motor drive board defective • IPU defective
Remedy: 1. Check the harness connection to the IPU. 2. Check the harness connection inside the laser unit YM. 3. Replace the polygon motor drive board. 4. Replace the IPU.
Description: Polygon motor error 1: Laser Unit CK The polygon mirror motor of LD unit YM does not reach the targeted operating speed within the prescribed time.
Causes: • Harness to the IPU disconnected • Harness inside the laser unit CK disconnected • Polygon motor drive board defective • IPU defective
Remedy: 1. Check the harness connection to the IPU. 2. Check the harness connection inside the laser unit CK. 3. Replace the polygon motor drive board. 4. Replace the IPU.
Description: Polygon motor error 3: Laser Unit CK The polygon motor stops operating while the LD units of the laser unit CK are firing.
Causes: • Harness to the IPU disconnected • Harness inside the laser unit CK disconnected • Polygon motor drive board defective • IPU defective
Remedy: 1. Check the harness connection to the IPU. 2. Check the harness connection inside the laser unit CK. 3. Replace the polygon motor drive board. 4. Replace the IPU.
Description: FGATE ON error: Bk The PFGATE ON signal does not assert within 20 ms after processing the image in normal job or MUSIC for start position K.
Causes: • Poor connection between BCU and IPU. • Defective IPU
Remedy: 1. Check the connection between the BCU and the IPU. 2. Replace the IPU.
Description: FGATE OFF error: Bk • The PFGATE ON signal still asserts within prescribed time after processing the image in normal job or MUSIC for end position K.
Causes: • Poor connection between BCU and IPU. • Defective IPU
Remedy: 1. Check the connection between the BCU and the IPU. 2. Replace the IPU.
Description: FGATE ON error: Y The PFGATE ON signal does not assert within 20 ms after processing the image in normal job or MUSIC for start position Y.
Causes: • Poor connection between BCU and IPU. • Defective IPU
Remedy: 1. Check the connection between the BCU and the IPU. 2. Replace the IPU.
Description: FGATE OFF error: Y • The PFGATE ON signal still asserts within the prescribed time after processing the image in normal job or MUSIC for end position Y.
Causes: • Poor connection between BCU and IPU. • Defective IPU
Remedy: 1. Check the connection between the BCU and the IPU. 2. Replace the IPU.
Description: FGATE ON error: C The PFGATE ON signal does not assert within 20 ms after processing the image in normal job or MUSIC for start position C.
Causes: • Poor connection between BCU and IPU • Defective IPU
Remedy: 1. Check the connection between the BCU and the IPU. 2. Replace the IPU.
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.