Description: FGATE OFF error: C • The PFGATE ON signal still asserts within the prescribed time after processing the image in normal job or MUSIC for end position C.
Causes: • Poor connection between BCU and IPU • Defective IPU
Remedy: 1. Check the connection between the BCU and the IPU. 2. Replace the IPU.
Description: FGATE ON error: M The PFGATE ON signal does not assert within 20 ms after processing the image in normal job or MUSIC for start position M.
Causes: • Poor connection between BCU and IPU • Defective IPU
Remedy: 1. Check the connection between the BCU and the IPU. 2. Replace the IPU.
Description: FGATE OFF error: M • The PFGATE ON signal still asserts within the prescribed time after processing the image in normal job or MUSIC for end position M.
Causes: • Poor connection between BCU and IPU • Defective IPU
Remedy: 1. Check the connection between the BCU and the IPU. 2. Replace the IPU.
Description: Laser synchronizing detection error: Start position [Y]: LD1. The laser synchronizing detection signal for the start position of the LDB [Y], [M], [C] or [K] is not detected while the LDB unit is in the READY state.
Causes: • Disconnected or defective harness to synchronizing detector for start position • Defective laser synchronizing detector for start position • Defective LDB
Remedy: 1. Check the harness connection between IPU and laser unit or around OPI. 2. Check the connectors inside the laser unit. 3. Replace the laser synchronizing detector for start position. 4. Replace the laser unit.
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.