Description: TD sensor adjustment error: K. During TD sensor initialization, the output value of the black, magenta, cyan, or yellow TD sensor is not within the range of the specified value (default: 2.5V) ±0.1V
Description: TD sensor adjustment error: C. During TD sensor initialization, the output value of the black, magenta, cyan, or yellow TD sensor is not within the range of the specified value (default: 2.5V) ±0.1V
Description: TD sensor adjustment error: M. During TD sensor initialization, the output value of the black, magenta, cyan, or yellow TD sensor is not within the range of the specified value (default: 2.5V) ±0.1V
Description: TD sensor adjustment error: Y. During TD sensor initialization, the output value of the black, magenta, cyan, or yellow TD sensor is not within the range of the specified value (default: 2.5V) ±0.1V
Description: Quenching error: K. The drum potential sensor for a color detects 2.0V (Vd: 400V) or more for 0.3 seconds after the charge corona wire has turned off.
Causes: • Disconnected or broken harness of the quenching lamp • Dirty surface of the quenching lamp glass
Remedy: 1. Check the harness or harness connection. 2. Clean the surface of the quenching lamp glass.
Description: Quenching error: C. The drum potential sensor for a color detects 2.0V (Vd: 400V) or more for 0.3 seconds after the charge corona wire has turned off.
Causes: • Disconnected or broken harness of the quenching lamp • Dirty surface of the quenching lamp glass
Remedy: 1. Check the harness or harness connection. 2. Clean the surface of the quenching lamp glass.
Description: Quenching error: M. The drum potential sensor for a color detects 2.0V (Vd: 400V) or more for 0.3 seconds after the charge corona wire has turned off.
Causes: • Disconnected or broken harness of the quenching lamp • Dirty surface of the quenching lamp glass
Remedy: 1. Check the harness or harness connection. 2. Clean the surface of the quenching lamp glass.
Description: Quenching error: Y. The drum potential sensor for a color detects 2.0V (Vd: 400V) or more for 0.3 seconds after the charge corona wire has turned off.
Causes: • Disconnected or broken harness of the quenching lamp • Dirty surface of the quenching lamp glass
Remedy: 1. Check the harness or harness connection. 2. Clean the surface of the quenching lamp glass.
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.