Description: Toner bottle motor error: K. If the error flag occurs for a toner bottle motor 5 times, the machine issues this SC. This error flag is calculated as follows. • The error flag of the toner bottle motor is made when the machine detects a LOCK signal of the toner bottle motor for 0.9 seconds during the toner bottle motor rotating (1 second). • The error flag of the toner bottle motor is cleared when the machine detects a LOCK signal of the toner bottle motor less than 0.9 seconds during the toner bottle motor rotating (1 second).
Causes: • Solidified toner in the toner bottle • Toner supply tube bent • Incorrect setting of the toner bottle • Broken toner bottle
Remedy: 1. Shake the toner bottle five or six times. 2. Check if the toner supply tube to sub-hopper unit is bent. 3. Check and reinstall the toner bottle. 4. Replace the toner bottle.
Description: Toner bottle motor error: C. If the error flag occurs for a toner bottle motor 5 times, the machine issues this SC. This error flag is calculated as follows. • The error flag of the toner bottle motor is made when the machine detects a LOCK signal of the toner bottle motor for 0.9 seconds during the toner bottle motor rotating (1 second). • The error flag of the toner bottle motor is cleared when the machine detects a LOCK signal of the toner bottle motor less than 0.9 seconds during the toner bottle motor rotating (1 second).
Causes: • Solidified toner in the toner bottle • Toner supply tube bent • Incorrect setting of the toner bottle • Broken toner bottle
Remedy: 1. Shake the toner bottle five or six times. 2. Check if the toner supply tube to sub-hopper unit is bent. 3. Check and reinstall the toner bottle. 4. Replace the toner bottle.
Description: Toner bottle motor error: M. If the error flag occurs for a toner bottle motor 5 times, the machine issues this SC. This error flag is calculated as follows. • The error flag of the toner bottle motor is made when the machine detects a LOCK signal of the toner bottle motor for 0.9 seconds during the toner bottle motor rotating (1 second). • The error flag of the toner bottle motor is cleared when the machine detects a LOCK signal of the toner bottle motor less than 0.9 seconds during the toner bottle motor rotating (1 second).
Causes: • Solidified toner in the toner bottle • Toner supply tube bent • Incorrect setting of the toner bottle • Broken toner bottle
Remedy: 1. Shake the toner bottle five or six times. 2. Check if the toner supply tube to sub-hopper unit is bent. 3. Check and reinstall the toner bottle. 4. Replace the toner bottle.
Description: Toner bottle motor error: Y. If the error flag occurs for a toner bottle motor 5 times, the machine issues this SC. This error flag is calculated as follows. • The error flag of the toner bottle motor is made when the machine detects a LOCK signal of the toner bottle motor for 0.9 seconds during the toner bottle motor rotating (1 second). • The error flag of the toner bottle motor is cleared when the machine detects a LOCK signal of the toner bottle motor less than 0.9 seconds during the toner bottle motor rotating (1 second).
Causes: • Solidified toner in the toner bottle • Toner supply tube bent • Incorrect setting of the toner bottle • Broken toner bottle
Remedy: 1. Shake the toner bottle five or six times. 2. Check if the toner supply tube to sub-hopper unit is bent. 3. Check and reinstall the toner bottle. 4. Replace the toner bottle.
Description: Development roller error: K. The development roller sensor for a color does not detect the rotation of the development roller for 0.5 seconds after the development motor for each color has turned on.
Causes: • Defective development unit drive gears • Defective development roller sensor
Remedy: 1. Replace the development unit drive gears. 2. Replace the development roller sensor.
Description: Development roller error: C. The development roller sensor for a color does not detect the rotation of the development roller for 0.5 seconds after the development motor for each color has turned on.
Causes: • Defective development unit drive gears • Defective development roller sensor
Remedy: 1. Replace the development unit drive gears. 2. Replace the development roller sensor.
Description: Development roller error: M. The development roller sensor for a color does not detect the rotation of the development roller for 0.5 seconds after the development motor for each color has turned on.
Causes: • Defective development unit drive gears • Defective development roller sensor
Remedy: 1. Replace the development unit drive gears. 2. Replace the development roller sensor.
Description: Development roller error: Y. The development roller sensor for a color does not detect the rotation of the development roller for 0.5 seconds after the development motor for each color has turned on.
Causes: • Defective development unit drive gears • Defective development roller sensor
Remedy: 1. Replace the development unit drive gears. 2. Replace the development roller sensor.
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.