Description: Fusing lamp (Center) thermistor not reloaded 2 The heater (Center) thermistor does not reach the reload temperature 50 seconds after the start of motor rotation.
Causes: • Fusing lamp Disconnected • The over temperature prevention mechanism started working
Description: Fusing (Center) heater stay ON The thermistor (center) has not detected the target temperature, even after the fusing heater stays ON for more than 30 seconds after reloading.
Causes: • Deformed or floating thermistor • Broken fusing lamp wire • The overtemperature prevention mechanism started working.
Description: Zero-crossing error (adhered relay contact) When the fusing relay is in an OFF state, a "zero-crossing interrupt request" occurs in 50 ms.
Remedy: • Turn the main power off/on. • Replace the PSU when fusing relay is broken. • Check the connection between PSU – engine board. • Replace the board and/or harness
Description: Zero-crossing error (bad relay contact) If a "zero-crossing interrupt request" does not occur when the fusing relay is in an ON state, an error results.
Remedy: • Turn the main power off/on. • Replace the PSU when fusing relay is broken. • Check the connection between PSU – engine board. • Replace the board and/or harness. • Replace the PSU fuse (24VS) if it is blown
Description: Zero-crossing error (low frequency error) The number of zero-crossing interrupts does not reach a certain value in 500 ms.
Causes: The frequency of the commercial power supply line is unstable.
Remedy: • Turn the main power off/on. • Check the connection of commercial power supply line • Check the connection between PSU – engine board. • Replace the board and/or harness
Description: Thermistor broken (Edge) While a fusing heater works, temperatures of -20°C or less during a consecutive 9 seconds are detected more than 10 times.