Description: Engine serial communication error (Time-out) No response over the specified time.
Causes: • Controller board or software failure • Connection failure may exist between controller board and engine board • Engine board or software failure
Remedy: • Check the connection between controller board and engine board. • Turn the main power off/on.
Description: Engine serial communication error (Retry-Over) When commands are sent in the normal mode (ESIF_LECI_NORMAL), communication fails over the upper limit numbers (3 times) of command byte retry.
Causes: • Controller board or software failure • Connection failure may exist between controller board and engine board • Engine board or software failure
Remedy: • Check the connection between controller board and engine board. • Turn the main power off/on.
Description: Engine serial communication error (Download Error) In the download command mode (ESIF_LECI_DLCOM) or download data mode (ESIF_LECI_DLDAT), a communication error is returned from engine.
Causes: • Controller board or software failure • Connection failure may exist between controller board and engine board • Engine board or software failure
Remedy: • Check the connection between controller board and engine board. • Turn the main power off/on.
Description: Engine serial communication error (UART Error) UART receive errors (Break condition, Framing, Parity or Overrun error) are detected.
Causes: • Controller board or software failure • Connection failure may exist between controller board and engine board • Engine board or software failure
Remedy: • Check the connection between controller board and engine board. • Turn the main power off/on.
Description: Remote Service Modem Communication Error (Dialup authentication failure) • An error related to communication (dialup connection, modem board etc.) using the RC Gate Type M was detected or an error that prevents RC Gate operation was detected at power on. • Displayed only when an error is detected while RC Gate is operating. • SC is not issued if an error occurs during RC Gate installation (because it can be referenced using SP).
Causes: Dialup authentication failure
Remedy: Check the following SPs. • SP5-816-156 • SP5-816-157
Description: Remote Service Modem Communication Error (dialup failing because of incorrect modem configuration) • An error related to communication (dialup connection, modem board etc.) using the RC Gate Type M was detected or an error that prevents RC Gate operation was detected at power on. • Displayed only when an error is detected while RC Gate is operating. • SC is not issued if an error occurs during RC Gate installation (because it can be referenced using SP).
Causes: Dialup failing because of incorrect modem configuration
Remedy: Check if the setting of SP5-816-160 is correct. If it is correct, then there is a software bug.
Description: Remote Service Modem Communication Error (insufficient current or connection fault) • An error related to communication (dialup connection, modem board etc.) using the RC Gate Type M was detected or an error that prevents RC Gate operation was detected at power on. • Displayed only when an error is detected while RC Gate is operating. • SC is not issued if an error occurs during RC Gate installation (because it can be referenced using SP).
Causes: Insufficient current or connection fault
Remedy: The line is not supported and nothing can be done.
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.