Code: 202

Description: Polygon motor error 1: ON timeout
The polygon mirror motor does not reach the targeted operating speed within 10 sec. after turning on or changing speed
Causes: • Polygon motor/driver board harness loose or broken • Polygon motor/driver board defective • Laser optics unit defective • IPU defective

Code: 203

Description: Polygon motor error 2: OFF timeout
The polygon mirror motor does not leave the READY status within 3 sec. after the polygon motor switched off.
Causes: • Polygon motor/driver board harness loose or broken • Polygon motor/driver board defective • Laser optics unit defective • IPU defective

Code: 204

Description: Polygon motor error 3: XSCRDY signal error
The SCRDY_N signal remains HIGH for 200 ms while the LD unit is firing.
Causes: • Polygon motor/driver board harness loose or broken • Polygon motor/driver board defective • Laser optics unit defective • IPU defective

Code: 220

Description: Laser synchronizing detection error: start position LD0
The laser synchronizing detection signal for the start position of the LDB is not output for two seconds after LDB unit turns on while the polygon motor is rotating normally
Causes: • Disconnected cable from the laser synchronizing detection unit or defective connection • Defective laser synchronizing detector • Defective LD board • Defective BCU

Code: 221

Description: Laser synchronizing detection error: start position LD1
The laser synchronizing detection signal for the start position of the LDB is not output for two seconds after LDB unit turns on while the polygon motor is rotating normally.
Causes: • Disconnected cable from the laser synchronizing detection unit or defective connection • Defective laser synchronizing detector • Defective LD board • Defective BCUa

Code: 230

Description: FGATE ON error
The FGATE signal does not assert within the prescribed time. (The BCU generates the FGATE signal and sends it to the LD unit when the registration sensor switches on.)
Causes: • BCU defective • BCU, Controller board harness loose or broken • Controller board defective.

Code: 231

Description: FGATE OFF error
The FGATE signal does not assert within the prescribed time. (The BCU generates the FGATE signal and sends it to the LD unit when the registration sensor switches on.)
Causes: • BCU defective • BCU, Controller board harness loose or broken • Controller board defective

Code: 240

Description: LD error
The IPU detected a problem at the LD unit.
Causes: • Worn-out LD • Disconnected or broken harness of the LD.