Description: Fusing overheat error 1 (software detection) A fusing temperature (at the end) of over 230°C (446°F) is detected for 1 second by the fusing thermistors at the center or at either end of the fusing roller.
Causes: • Power supply unit defective • I/O board (IOB) defective • BICU defective • TRIAC short on PSU (PSU defective)
Description: Fusing overheat error 1 (hardware detection) A fusing temperature (at the end) over 250°C is detected by the fusing temperature monitor circuit in the BICU board.
Description: Zero cross frequency error When the zero cross signal is 66 or more and it is detected 10 times or more in 11 detections, the machine determines that input 60 Hz and SC557 occurs.
Description: Fusing unit jam The fusing sensor detected a fusing unit paper late jam three times. The paper was late and the fusing exit sensor could not detect the paper three times.
Causes: • Remove the paper that is stopped in the fusing unit. • Check that the fusing unit is clean and has no obstacles in the paper feed path. • If the error persists, replace the fusing unit.
Description: Paper feed unit communication error While the IOB communicates with a peripheral, an SC code is displayed if one of following conditions occurs. • The IOB receives the break signal which is generated by the peripheral only just after the main switch is turned on. • The IOB receives the break signal which is generated by URAT.
Causes: • Defective main control board of the peripheral • Defective BCU or IOB • Disconnected peripheral
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.