Description: Fusing temperature warm-up error(center) This SC is generated if the following condition occurs: • The thermistor (center) does not detect an 8°C increment in the fusing temperature for 7.5 sec. just after the fusing temperature reached 45C. • The temperature of the center thermistor does not reach the target temperature for 28 seconds after the fusing lamps turned on.
Causes: • Thermistor warped or broken
Code: 543
Description: Fusing overheat error 1 (software detection) A fusing temperature (at the center) of over 230°C (446°F) is detected for 1 second by the fusing thermistors at the center or at either end of the fusing roller.
Causes: • Power supply unit defective • I/O board (IOB) defective • BICU defective • TRIAC short on PSU (PSU defective)
Code: 544
Description: Fusing overheat error 1 (hardware detection) A fusing temperature (at the center) over 250°C is detected by the fusing temperature monitor circuit in the BICU board.
Description: Zero cross error • The zero cross signal is detected three times even though the heater relay is off when turning on the main power. • The zero cross signal is not detected for 2 seconds even though the heater relay is on after turning on the main power or closing the front door. • The detection error occurs twice or more in the 11 zero cross signal detections. This error is defined when the detected zero cross signal is less than 45.
Description: Fusing temperature warm-up error (end) This SC is generated if the following condition occurs: • The thermistor (end) does not detect an 8°C increment in the fusing temperature for 7.5 sec. just after the fusing temperature reached 45°C. • The temperature of the end thermistor does not reach the target temperature for 31 seconds after the fusing lamps turned on.