Description: Broken fusing (End) thermistor wire At least ten times, the temperature is detected to stay at 0 deg C or less for three seconds.
Causes: - Broken thermistor wire - Bad connector contact
Remedy: • Clear the SP: fusing SC. • Check the connector connection. • Replace the fusing (End) thermistor.
Code: 552-02
Description: Fusing (End) thermistor not reloaded 1 The heating (End) thermistor does not reach 80 deg C 7.7 seconds after the start of heat control (during normal startup control)
Causes: • Stained thermopile lens • Deformed or floating thermistor • Input voltage out of range • The overtemperature prevention mechanism started working
Remedy: • Clear the SP: fusing SC. • Replace the Fusing Unit.
Code: 552-03
Description: Fusing (End) thermistor not reloaded 2 The heating (End) thermistor does not reach 80 deg C 7.7 seconds after the start of heat control (during normal startup control)
Causes: • Stained thermopile lens • Deformed or floating thermistor • Input voltage out of range • The overtemperature prevention mechanism started working
Remedy: • Clear the SP: fusing SC. • Replace the Fusing Unit.
Code: 552-04
Description: Fusing (End) thermistor not reloaded 3 The heating (End) thermistor does not reach 80 deg C 7.7 seconds after the start of heat control (during normal startup control)
Causes: • Stained thermopile lens • Deformed or floating thermistor • Input voltage out of range • The overtemperature prevention mechanism started working
Remedy: • Clear the SP: fusing SC. • Replace the Fusing Unit.
Code: 553-00
Description: Fusing (End) thermistor high-temperature detected (software) The temperature is detected to stay at 230 deg C or higher for one second.
Causes: • Shorted triac • Failed Engine Board
Remedy: • Clear the SP: fusing SC. • Replace the PSU. • Replace the Engine Board.
Code: 554-00
Description: Fusing (End) thermistor high-temperature detected (software) The hardware high-temperature error Sensor flag is detected at 10 ms intervals.
Causes: • Damaged triac (shorted) • Failed engine control board • Failed fusing thermopile • Failed fusing thermistor • Abnormal fusing control software behavior • The PWM signal is continuously supplied from the IH inverter (due to a software or temperature Sensor error).
Remedy: • Clear the SP: fusing SC. • Replace the PSU. • Replace the Engine Board. • Replace the fusing thermopile. • Replace the Fusing Unit.
Code: 555-00
Description: Fusing (End) heater stay ON The fusing (End) heater stays ON for 8.6 seconds or more when in stand-by state (or the fusing roller is not rotating).
Causes: • Deformed or floating thermistor • Broken fusing lamp wire • The overtemperature prevention mechanism started working
Remedy: • CLEAR THE SP: FUSING SC. • Replace the thermistor. • Replace the fusing (End) lamp.
Code: 557-00
Description: Zero-crossing frequency exceeded The number of zero-crossing interrupts exceeds a certain value in 500 ms.
Causes: The frequency of the commercial power supply line is unstable or noise occurs