Description: Fusing (End) thermistor not reloaded 1 The heating (End) thermistor does not reach 80 deg C 7.7 seconds after the start of heat control (during normal startup control)
Causes: • Stained thermopile lens • Deformed or floating thermistor • Input voltage out of range • The overtemperature prevention mechanism started working
Remedy: • Clear the SP: fusing SC. • Replace the Fusing Unit.
Description: Fusing (End) thermistor not reloaded 2 The heating (End) thermistor does not reach 80 deg C 7.7 seconds after the start of heat control (during normal startup control)
Causes: • Stained thermopile lens • Deformed or floating thermistor • Input voltage out of range • The overtemperature prevention mechanism started working
Remedy: • Clear the SP: fusing SC. • Replace the Fusing Unit.
Description: Fusing (End) thermistor not reloaded 3 The heating (End) thermistor does not reach 80 deg C 7.7 seconds after the start of heat control (during normal startup control)
Causes: • Stained thermopile lens • Deformed or floating thermistor • Input voltage out of range • The overtemperature prevention mechanism started working
Remedy: • Clear the SP: fusing SC. • Replace the Fusing Unit.
Description: Fusing (End) thermistor high-temperature detected (software) The hardware high-temperature error Sensor flag is detected at 10 ms intervals.
Causes: • Damaged triac (shorted) • Failed engine control board • Failed fusing thermopile • Failed fusing thermistor • Abnormal fusing control software behavior • The PWM signal is continuously supplied from the IH inverter (due to a software or temperature Sensor error).
Remedy: • Clear the SP: fusing SC. • Replace the PSU. • Replace the Engine Board. • Replace the fusing thermopile. • Replace the Fusing Unit.
Description: Fusing (End) heater stay ON The fusing (End) heater stays ON for 8.6 seconds or more when in stand-by state (or the fusing roller is not rotating).
Causes: • Deformed or floating thermistor • Broken fusing lamp wire • The overtemperature prevention mechanism started working
Remedy: • CLEAR THE SP: FUSING SC. • Replace the thermistor. • Replace the fusing (End) lamp.