Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi Ricoh Aficio SPC730DN — Trang 11/15

Code: 670-00

Description: Engine startup error
Case 1: • When the main power is turned on or when the machine is recovering from energy saver mode, the /ENGRDY signal assertion fails. • After the main power is turned on, the engine does not make the EC response within the specified time. • After the main power is turned on, the engine does not make the PC response within the specified time. • Writing of the Rapi driver failed (not recognized by PCI). Case 2: After the /ENGRDY signal assertion, an unintended shutdown is detected.
Causes: Case 1: • The Engine Board does not start up. Case 2: The Engine Board is reset at an unintended timing. Check the connection and the contact between the Engine Board and the Controller Board again. If the error is 100% reproducible, replace the Engine Board. If the error is still not resolved after the replacement, replace the Controller Board and junction boards.
Remedy:

Code: 672

Description: Controller startup error
• When communication between the controller and the operation panel does not begin normally after the machine is powered on or if communication is interrupted after a normal startup. • When the controller does not send an attention code (FDH) or attention acknowledge code (FEH) within 15 to 30 seconds after the operation panel is reset. • After the operation panel issues a command to check the communication line with the controller at 30-second intervals, the controller fails to respond twice.
Causes: 672-10 After the machine is powered on, communication (receiving) between the controller and operation panel is unable to begin normally. 672-11 After the machine is powered on, communication (sending) between the controller and operation panel is unable to begin normally, or data transmission after startup fails. 672-12 Communication with the controller is interrupted after a normal startup. 672-13 The operation panel detects that the controller is down for reasons other than those described above. 672-99 The software for the operation panel (OCS) is aborted.
Remedy: Turn the main switch off and on.

Code: 674-01

Description: Transfer error
An M2P error has occurred.
Causes: Defective Controller Board/software
Remedy: Turn the main switch off and on.

Code: 674-02

Description: Transfer error
A PCI error interrupt is generated by the expanded engine ASIC (SELENE,SELENE2)
Causes: PCI error
Remedy: Turn the main switch off and on.

Code: 688-00

Description: PRREQ signal not asserted
The print request signal (PRREQ) signal is not asserted within the prescribed time after paper reaches the registration stand-by position,
Causes: - Noise - Engine Board error
Remedy: • Turn the power OFF and then ON • Replace the Engine Board.

Code: 790-00

Description: Maximum number of banks (paper tray units) exceeded error
When the power is turned ON, the number of mounted paper tray units is detected and the number exceeds three.
Causes: The number of mounted paper tray units exceeds the specifications.
Remedy: Reduce the number of mounted paper tray units according to the specifications.

Code: 816

Description: Error detected by Energy efficient I/O subsystem
When the energy efficient I/O subsystem detects some kind of error.
Causes: • Defective energy efficient I/O subsystem • The energy efficient I/O subsystem has found an error in the Controller Board (no response). • An error was detected during the preparation for the STR migration.
Remedy: Turn the main switch off and on.

Code: 820-00

Description: Self-diagnostic error: CPU
No interrupt is supposed to occur after the Interrupt 0 is used.
Causes: • Defective CPU device • Defective ASIC device
Remedy: Replace the Controller Board.
Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie