Description: Clamper error The MPU cannot detect the clamper position sensor signal (open or closed) within 3.0 seconds after the clamper motor turns on.
Causes: Clamper drive Clamper sensors Clamper motor
Code: E-01
Description: Cutter error The cutter HP sensor does not turn on within 3.0 seconds after the cutter motor turns on.
Causes: Cutter drive Cutter switch Cutter motor
Code: E-02
Description: Paper Table Drive error The paper height sensor or the table lower limit sensor does not turn on within 7.5 seconds after the table motor turn on.
Description: Thermal Head Overheat The temperature of the thermal head is grater than 54C when the Start key is pressed.
Causes: Overheat (wait for the thermal head to cool down) Thermal head
Code: E-06
Description: Main Motor error The CPU cannot detect the master eject position sensor (drum HP) signal within 5.0 seconds after the main motor turn on.
Causes: Main motor drive Main motor Motor drive board Master eject position sensor
Code: E-09
Description: Thermal Head Thermistor Open The thermistor output voltage is over 2.82 volts.
Causes: Thermal head thermistor Thermal head connector
Code: E-10
Description: Thermal Head Energy Pulse error The CPU detects an abnormal ID signal from the thermal head energy control pulse.
Causes: Thermal head connector Thermal head MPU
Code: E-12
Description: Pressure Plate error The pressure plate home position sensor signal is not detected within 6.0 seconds after the pressure plate motor turn on.
Causes: Pressure plate drive Pressure plate motor Plate position sensors