Code :
  • Code: 344 S04
  • Description: Cleaning motor timeout 2 HP sensor does not go ON even after the motor rotates for the specific time period to move the cleaning motor to the front retracting position.
  • Code: 345 S04
  • Description: Error on the Cleaning Motor When the cleaning motor rotated, the pulse count was below the parameter after completion of moving.
  • Code: 346 S04
  • Description: Cleaning motor timeout 3 HP sensor does not go OFF even after the motor rotates for the specific time period to move the cleaning motor to the rear.
  • Code: 3xx
  • Description: Heads and related parts
  • Code: 400 S10
  • Description: FL transfer motor lock (Detailed No. 1: timeout) There was no input interrupt from the FL transfer motor FG sensor during FL transfer motor operation, even after the specified time elapsed.
  • Code: 402 S10
  • Description: Feed tray 1 elevator motor lock (Detailed No. 1: timeout) The FL feed tray 1 upper limit sensor fails to activate after the FL feed tray 1 elevator motor turns ON, even after the specified time elapses. * This error can be cleared by opening feed tray 1.
  • Code: 403 S10
  • Description: Feed tray 1 elevator motor lock (Detailed No. 2: overcurrent) An overcurrent was detected in the FL feed tray 1 elevator motor. * This error can be cleared by opening feed tray 1.
  • Code: 404 S10
  • Description: Feed tray 2 elevator motor lock (Detailed No. 1: timeout) The FL feed tray 2 upper limit sensor fails to activate after the FL feed tray 2 elevator motor turns ON even after the specified time elapses. * This error can be cleared by opening feed tray 2.