Causes: 1. Seal tape is removed? 2. GND OPC is well grounded? 3. LSU running well? 4. Biss voltage is normal? 5. Lower toner?
Remedy: 1. Removing seal tipe 2. Measure the resistance between frame ground and the ground spring attached frame. Confirm stable ground. Unless bad ground, detach cabinet, check where is bad point 3.Adjust LSU or replace it 4. Normal Dev bias = -300V 5. Shake toner cartridge and print.If a liitke good, toner is empty
Causes: 1. Check seal tape removing 2. LSU light power normal? 3. Enough toner? 4. High charger voltage? 5. Lower bias voltage 6. Contamination of high voltage contact 7. Transfer volatge and roller
Remedy: 1. Check and remove tape 2. LSU light power check is difficult. Compare with new one and check. 3. Check toner and developer counter 4-5. Measure all high voltage output 6. Leakage toner cause bad contact and increase contact resistance. Clean contaminated area.