Code :
- Code: C41D
- Description: The backup roller thermistor is detected of its opencircuit. (At low temperature)
- Causes: Does this error recur?
- Remedy: Turn on the power again. Replace the fuser unit.
- Code: C41E
- Description: Compensation Thermistor Error
- Causes: Is the error message displayed? Does this error recur?
- Remedy: Turn on the power again. After leaving a printer for 30 minutes, turn on the power again.
- Code: C449, C446
- Description: The fuser thermistor has detected an abnormal temperature (high temperature or low temperature.)
- Causes: Does this error recur? Does this error recur?
- Remedy: Turn on the power again. Replace the fuser unit. Replace the low voltage power supply unit.
- Code: C44A
- Description: Thermistor Slope Error
- Causes: Is the error message displayed? Does this error recur?
- Remedy: Turn on the power again. After leaving a printer for 30 minutes, turn on the power again.
- Code: C468, C466
- Description: The backup roller thermistor has detected an abnormal temperature (high temperature or low temperature.)
- Causes: Does this error recur? Does this error recur?
- Remedy: Turn on the power again. Replace the fuser unit. Replace the low voltage power supply unit.
- Code: C46A, C46B
- Description: Compensation Heater Temp high Compensation Heater Temp Low
- Causes:
- Remedy: Turn on the power,after 30min.
- Code: C46C
- Description: Power Supply Thermistor Short Error. (When temperature is high)
- Causes:
- Remedy: Turn off the Power of the printer and back on.
- Code: C46D
- Description: Power Supply Thermistor Open Error (When temperature is low)
- Causes:
- Remedy: Turn off the Power of the printer and back on.