Các lỗi thường gặp

Code :
  • Code: C5B5
  • Description: When LCF is setting, Tray2 Clock Adjust Error or Tray3 Clock Adjust Error is report from PU. Interchange the error to LCF Clock Adjust Error by CU.
  • Causes:
  • Remedy: Replace the Tray board
  • Code: C91E
  • Description: When separate toner is setting, occur the error in case the ID and TC is same Tag.
  • Causes: Set the correct tag in ID and TC.
  • Remedy:
  • Code: C91F
  • Description: Detect to receive the each color. Change the ERR04
  • Causes:
  • Remedy: Set the correct tag in ID and TC.
  • Code: C921
  • Description: AC voltage zero-crossing error
  • Causes:
  • Remedy: C h e ck t h e AC voltage. Change the Lowvoltage board or PU board.
  • Code: C940
  • Description: Engine control logic has an error.
  • Causes: Does this error recur?
  • Remedy: Yes Turn off the power of the printer and back on. Replace the PU board
  • Code: C96A
  • Description: High voltage power supply interface error.
  • Causes: Is the cable connecting the PU board to the high voltage unit connected normally? Have you checked defective contact of contactor points?
  • Remedy: Re-connect them normally. Check for defective contact of the high voltage system. Replace the high voltage power supply.
  • Code: C9A0
  • Description: Offline stapler error
  • Causes:
  • Remedy: Change the offline stapler
  • Code: CE50
  • Description: Environment temperature is abnormal.
  • Causes: Does this error recur?
  • Remedy: Yes Turn off the power of the printer and back on. Replace the Board 8TH.