Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi Toshiba e-Studio 477S — Trang 4/15

Code: C46E

Description: Power Supply Thermistor Temp High
Causes:
Remedy: Turn off the Power of the printer and back on.

Code: C46F

Description: Power Supply Thermistor Temp Low
Causes:
Remedy: Turn off the Power of the printer and back on.

Code: C4C0

Description: The fuse has blown out.
Causes: Is the fuser unit installed normally? Does this error recur?
Remedy: After cleaning the connecting connector of the fuser unit, re-install the fuser unit. Turn on the power again. After checking for the sure cable connection, replace the PU or Board IBY.

Code: C4E3

Description: Fuser motor lock error
Causes: Fuser does not rotate normally. Does this error recur?
Remedy: Check if the fuser is installed normally or not. Replace the fuser. Replace the fuser motor.

Code: C4FA

Description: Media wrapped around the fuser error
Causes: Media has wrapped around the fuser.
Remedy: Turn off the power. Replace the fuser.

Code: C56A ... C56D

Description: Option unit I/F error (C56A=Duplex Unit, C56B=2nd Tray, C56C=3rd Tray C56D=4th Tray)
Causes: Does this error recur? Does this error recur?
Remedy: Turn on the power again. Check for sure connection of the connectors. Replace the option unit.

Code: C56E

Description: When LCF is setting,Tray2 Unit I/F Error or Tray3 Unit I/F Error is report from PU. Interchange the error to LCF Unit I/F Error by CU. Occur:When communication has dropped off.
Causes:
Remedy: Turn on the power again.

Code: C5A1

Description: Read/write error of the engine EEPROM is detected.
Causes: Does this error recur?
Remedy: Yes Turn off the power of the printer and back on. Replace the PU board.