Mã lỗi Toshiba e-Studio 477S — Trang 7/15

Code: CE51

Description: Environment humidity is abnormal./ Humidity sensor is not connected.
Causes: Does this error recur?
Remedy: Yes Turn off the power of the printer and back on. Replace the Board 8TH.

Code: CE52

Description: Dew condensation of the printer is detected.
Causes: This error can easily occur when a printer is brought in to indoor from outdoor. Leave the printer for 2 hours or half day under room temperature, and turn on the power again. Does this error recur?
Remedy: Yes After leaving a printer under room temperature, turn on the power again. Replace the Board 8TH.

Code: CE7A

Description: ID Up/Down position detection error
Causes: Is the ID unit caught by anything when it is removed and reinstalled? Does this error recur?
Remedy: Re-install the ID unit. Turn on the power again. Replace the high voltage power supply.

Code: CE85

Description: LED head detection error (CE85=K)
Causes: Is the LED head connected normally? Is the LED HEAD fuse brown? Does this error recur?
Remedy: Install the LED head unit normally. Check the LED HEAD fuse. After checking fuse Turn on the power again. For the method of checking the LED head unit fuse, refer to section 7.6.

Code: D108

Description: When LCF can not Lift up.
Causes:
Remedy: Set the Paper of the LCF Tray again.

Code: D109

Description: Detect the paper capacity is over.
Causes:
Remedy: Set the Paper of the LCF Tray again.

Code: D216

Description: Reversal cover is open.
Causes:
Remedy: Close the Exit Cover

Code: D3F1

Description: Occur:The drum counter is over the life limit, and detect toner empty.
Causes:
Remedy: Push the ONLINE SW when change the new Image Drum.